当前位置: 首页 > 详情页

A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results

文献详情

资源类型:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Chinese Acad Med Sci, Dept Cardiol, Cardiovasc Inst, Beijing 100037, Peoples R China; [2]Chinese Acad Med Sci, Cardiac Catheterizat Lab, Cardiovasc Inst, Beijing 100037, Peoples R China; [3]Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China; [4]Peking Union Med Coll, Beijing 100037, Peoples R China; [5]Shenyang No Hosp, Dept Cardiol, Shenyang 110015, Liaoning, Peoples R China; [6]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiol, Beijing 100029, Peoples R China; [7]Peking Univ, Hosp 1, Dept Cardiol, Beijing 100044, Peoples R China; [8]Capital Med Univ, Beijing Chao Yang Hosp, Dept Cardiol, Beijing 100020, Peoples R China; [9]Chinese Peoples Liberat Army Gen Hosp, Dept Cardiol, Beijing 100853, Peoples R China; [10]Fourth Mil Med Univ, Xijing Hosp, Dept Cardiol, Xian 710032, Shaanxi, Peoples R China; [11]Harbin Med Coll, Affiliated Hosp 1, Dept Cardiol, Harbin 150001, Heilongjiang, Peoples R China; [12]Guangdong Prov Cardiovasc Inst, Dept Cardiol, Guangzhou 510080, Guangdong, Peoples R China; [13]Capital Med Univ, Beijing Friendship Hosp, Dept Cardiol, Beijing 100050, Peoples R China; [14]China Japan Friendship Hosp, Dept Cardiol, Beijing 100029, Peoples R China;
出处:
ISSN:

关键词: TIVOLI stent biodegradable polymer sirolimus-eluting stent clinical outcome

摘要:
Background Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently,investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease.Methods A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group:156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤40 mm,reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years,including major adverse cardiac events (cardiac death,myocardial infarction, or target-lesion revascularization) and stent thrombosis.Results Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25±0.33) mm vs. (0.57±0.55) mm, diff (95% CI)-0.23 (-0.32, -0.14), P <0.0001; in-segment (0.25±-0.33) mm vs. (0.42±-0.55) mm, diff (95% CI) -0.13 (-0.23, -0.02),P=0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P=0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P=0.0495) at 2 years. The two-year major adverse cardiac events (MACE) rate was lower for the TIVOLI group, but not significantly different (6.6% vs. 10.9%, P=0.1630).Conclusions TIVOLI was superior to ENDEAVOR stent with respect to late lumen loss at 8 months, and it yielded both lower rates of angiographic binary restenosis at 8 months and target lesion revascularization (TLR) at 2 years.The MACE rate at 2 years was comparable in both groups.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2009]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2009版] 出版当年五年平均 出版前一年[2008版] 出版后一年[2010版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]Randomized comparison of novel biodegradable polymer and durable polymer-coated cobalt-chromium sirolimus-eluting stents: Three-Year Outcomes of the I-LOVE-IT 2 Trial [2]Two-year safety evaluation of a biodegradable polymer sirolimus-eluting stent with increased drug elution and polymer absorption kinetics in complex patient and lesion cohort [3]Novel completed biodegradable polymer sirolimus-eluting stent versus durable polymer sirolimus-eluting stent in de novo lesions: nine-month angiographic and three-year clinical outcomes of HOPE trial [4]NOYA I: A Prospective Randomized Trial of the Biodegradable Polymer NOYA Sirolimus-Eluting Stent Compared with the Durable Polymer FIREBIRD 2 Sirolimus-Eluting Stent in Patients with Coronary Artery Disease: 9-Month Angiographic and 24-Month Clinical Results [5]Efficacy and safety of a second-generation biodegradable polymer sirolimus-eluting stent: One-year results of the CREDIT 2 trial [6]A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial [7]Nine-month angiographic and 2-year clinical follow-up of the NOYA biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo native coronary artery lesions: the NOYA I trial [8]Long-Term Outcomes With an Abluminal Groove-Filled Biodegradable Polymer Sirolimus-Eluting Stent Versus a Cobalt-Chromium Everolimus-Eluting Stent in Single De Novo Coronary Lesions: Four-Year Results of the TARGET I Randomized Controlled Trial [9]Safety and Efficacy of a Novel Abluminal Groove-filled Biodegradable Polymer Sirolimus-eluting Stent for the Treatment of De Novo Coronary Lesions: Two-Year Results From a Prospective Patient-level Pooled Analysis of TARGET Trials [10]A Randomized Comparison of The Second Generation Biodegradable Polymer Sirolimus-eluting Stent (EXCEL-II) and The First Generation EXCEL-I stent in Patients with De novo Coronary Lesions: Clinical and Angiographic Outcomes of the CREDIT II Trial