当前位置: 首页 > 详情页

[Stents coated with sirolimus and anti-CD34 antibody can optimize the performance of sirolimus-eluting stents].

| 认领 | 导出 |

文献详情

资源类型:

收录情况: ◇ 统计源期刊 ◇ 北大核心 ◇ CSCD-C ◇ 中华系列

机构: [1]Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
出处:
ISSN:

摘要:
To investigate the impact of the stents coated with sirolimus and anti-CD34 antibody on the short-term re-endothelialization and the long-term restenosis in Chinese Minipigs. Three different types of stents [bare-metal stent (BMS), sirolimus-eluting stent (SES) and anti-CD34 antibody and sirolimus-coated stent (ASES)] were randomly implanted in the coronary arteries of 22 Chinese Minipigs. At two weeks after stenting, coronary angiography and optical coherence tomography (OCT) were performed in 10 experimental animals. At three months after stenting, coronary angiography and OCT were performed in the remaining 12 experimental animals. Histopathologic examination was performed on the coronary artery segments containing stent after the animals were executed. (1) No in-stent thrombosis and parietal thrombus were found by coronary angiography, OCT and histopathologic examination at two weeks post stenting. OCT analysis showed that the covered ratio of stent struts by neointima in ASES group was higher than in SES group [(55.56 ± 35.27)% vs. (41.82 ± 23.28)%, P < 0.05]. The mean thickness of neointima in ASES group was significantly higher than in SES group [(89.0 ± 5.0) μm vs. (32.0 ± 4.9) μm, P < 0.01] and BMS group [(89.0 ± 5.0) μm vs. (44.0 ± 7.2) μm, P < 0.01]. Histopathologic and scanning electron microscopy examinations demonstrated that the covering level and quality of stent struts by neointima in BMS and ASES group were both better than in SES group. (2) At three months follow-up, quantitative coronary angiography analysis found that late in-stent lumen loss in ASES group was significantly lower than in BMS group [(0.18 ± 0.06) mm vs.(0.35 ± 0.06) mm, P < 0.05]. OCT analysis showed that the percent neointimal hyperplasia in ASES and SES group was significantly lower than in BMS group [(34.75 ± 2.64)% and (35.63 ± 2.07)% vs. (48.28 ± 3.25)%, both P < 0.01]. Histopathologic analysis demonstrated that the percent areal restenosis of ASES and SES group were both significantly lower than that of BMS group [(28.65 ± 5.64)% and (29.33 ± 6.07)% vs. (46.18 ± 8.25)%, both P < 0.05]. The stents coated with anti-CD34 antibody and sirolimus can attenuate the inhibitory effect of sirolimus on the re-endothelialization at two weeks after stenting and the anti-hyperplasia effect of sirolimus at three months after stenting.

语种:
第一作者:
第一作者机构: [1]Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, 100029, China
推荐引用方式(GB/T 7714):

资源点击量:17069 今日访问量:2 总访问量:918 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院