当前位置: 首页 > 详情页

The median effective dose (ED50) of cis-Atracurium for laryngeal mask airway insertion during general Anaesthesia for patients undergoing urinary surgery

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [a]Department of Anesthesiology, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China [b]Institute of Geriatrics, Beijing, 100053, China [c]National Clinical Research Center for Geriatric Disorders, Beijing, 100053, China [d]Department of Urinary Surgery, Xuanwu Hospital, Capital Medical University, Beijing, 100053, China
出处:
ISSN:

关键词: cis-Atracurium ED50 Laryngeal mask Sequential method Urinary surgery

摘要:
Background: In clinical practice, the laryngeal mask airway is an easy-to-use supraglottic airway device. However, the cis-atracurium dosage for laryngeal mask insertion has not been standardised. We aimed to determine the optimal dose of cis-atracurium using a sequential method for successful laryngeal mask insertion. Methods: The cohort study protocol is registered at clinicaltrial.gov (NCT-03668262). Twenty-three patients undergoing elective urinary surgery were sequentially administered cis-atracurium doses as follows: 150, 100, 70, 50, 30, and 20 μg·kg- 1. The main outcome involved the determination of the response to laryngeal mask airway insertion: ≥16 points and < 16 points indicated "satisfactory" and "unsatisfactory" responses, respectively. The median effective dose was estimated using the mean of the seven crossovers from "satisfactory" and "unsatisfactory" responses. The primary outcome involved the determination of the median effective dose (ED50) of cis-atracurium for laryngeal mask airway insertion. Results: The median effective dose of cis-atracurium was 26.5 μg·kg- 1 (95% CI 23.6-29.8) using the sequential method. Heart rate was decreased in the 50 μg·kg- 1 group compared to that in the 30 μg·kg- 1 group at timepoints T7, T8, and T10 (P = 0.0482, P = 0.0460, and P = 0.0236, respectively), but no difference was observed in the 20 μg·kg- 1 group. Systolic blood pressure was decreased in the 50 μg·kg- 1 group compared to that in the 20 μg·kg- 1 group at timepoints T2, T3, and T4 (P = 0.0159, P = 0.0233, and P = 0.0428, respectively). The train-of-four value was significantly lower in the 50 μg·kg- 1 group than in the 30 μg·kg- 1 group at timepoint T3 (P = 0.0326). Conclusions: The ED50 of cis-atracurium was 26.5 μg·kg- 1 for laryngeal mask airway insertion. Trial registration: Clinicaltrial.gov Registry, NCT03668262, Registered on 11 September 2018. © 2020 The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 麻醉学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 麻醉学
JCR分区:
出版当年[2018]版:
Q4 ANESTHESIOLOGY
最新[2023]版:
Q2 ANESTHESIOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院