当前位置: 首页 > 详情页

Reproducibility of Macular, Retinal Nerve Fiber Layer, and ONH Measurements by OCT in Rhesus Monkeys: The Beijing Intracranial and Intraocular Pressure (iCOP) Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China [2]Capital Med Univ, Dept Neurosurg, Beijing Tongren Hosp, Beijing 100730, Peoples R China [3]Capital Med Univ, Dept Ophthalmol, Beijing Xuanwu Hosp, Beijing 100730, Peoples R China [4]China Acad Chinese Med Sci, Hosp Eye, Dept Ophthalmol, Beijing, Peoples R China [5]Univ Heidelberg, Med Fac Mannheim, Dept Ophthalmol, D-6800 Mannheim, Germany
出处:
ISSN:

摘要:
PURPOSE. We evaluated repeatability and reproducibility of measurements of the retinal nerve fiber layer thickness (RNFLT), optic nerve head (ONH), and macular inner retinal layer (MIRL) by RTVue spectral-domain optical coherence tomography (OCT) in normal Rhesus monkeys. METHODS. The experimental study included 15 adult Rhesus macaque monkeys. RNFLT, ONH parameters (area of disc, cup, and rim; volume of cup and rim; and cup-to-disc ratios), and MIRL thickness were imaged at three separate examinations within one month. Each eye was imaged three times at the first examination, and once at each of the two following examinations. We determined the intra-session and inter-session (inter-visit) within-subject SD (Sw), precision (1.96 X Sw), coefficient of variation (CVw, 100 X Sw/overall mean), and intraclass correlation coefficient (ICC). RESULTS. For the intra-session repeatability, ICC values ranged between 0.97 and 1.00 for all ONH parameters, and between 0.80 and 0.98 for all regional RNFLT parameters, with a value of 0.97 for the average RNFLT. For the inter-session (inter-visit) reproducibility, ICC values ranged from 0.93-1.00 for the ONH measurements and from 0.63-0.97 for regional RNFLT parameters, with a value of 0.96 for the average RNFLT. Again, the ICC values were lowest in the temporal inferior and temporal superior regions. The ICC value for the average MIRL thickness was 0.95. CONCLUSIONS. Repeatability and reproducibility of spectral-domain OCT measurements of the RNFL, ONH, and MIRL were high in normal monkey eyes. Spectral-domain OCT may be suitable to assess changes in follow-up examinations of monkeys with experimental glaucoma. (Invest Ophthalmol Vis Sci. 2012;53:4505-4509) DOI:10.1167/iovs.12-9439

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2010]版:
Q1 OPHTHALMOLOGY
最新[2023]版:
Q1 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, Beijing 100730, Peoples R China [*1]Capital Med Univ, Beijing Tongren Eye Ctr, Beijing Tongren Hosp, Beijing Ophthalmol & Visual Sci Key Lab, 1 Dongjiaominxiang St, Beijing 100730, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17236 今日访问量:0 总访问量:925 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院