当前位置: 首页 > 详情页

Comparison of Black Hole Sign, Satellite Sign, and Iodine Sign to Predict Hematoma Expansion in Patients with Spontaneous Intracerebral Hemorrhage(Open Access)

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 预警期刊

机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China [3]Neuroradiology Department, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, No. 119 Nansihuanxilu, Fengtai District, Beijing, China [4]Department of Nuclear Medicine, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China
出处:
ISSN:

摘要:
Purpose. To discretely and collectively compare black hole sign (BHS) and satellite sign (SS) with recently introduced gemstone spectral imaging-based iodine sign (IS) for predicting hematoma expansion (HE) in spontaneous intracerebral hemorrhage (SICH). Methods. This retrospective study includes 90 patients from 2017 to 2019 who underwent both spectral computed tomography angiography (CTA) as well as noncontrast computed tomography (NCCT) within 6 hours of SICH onset along with subsequent follow-up NCCT scanned within 24 hours. We named the presence of any of BHS or SS as any NCCT sign. Two independent reviewers analyzed all the HE predicting signs. Receiver-operator characteristic curve analysis and logistic regression were performed to compare the predictive performance of HE. Results. A total of 61 patients had HE, out of which IS was seen in 78.7% (48/61) while BHS and SS were seen in 47.5% (29/61) and 41% (25/61), respectively. The area under the curve for BHS, SS, and IS was 63.4%, 67%, and 82.4%, respectively, while for any NCCT sign was 71.5%. There was no significant difference between IS and any NCCT sign (P=0.108). Multivariate analysis showed IS (odds ratio 68.24; 95% CI 11.76-396.00; P<0.001) and any NCCT sign (odds ratio 19.49; 95% CI 3.99-95.25; P<0.001) were independent predictors of HE whereas BHS (odds ratio 0.34; 95% CI 0.01-38.50; P=0.534) and SS (odds ratio 4.54; 95% CI 0.54-38.50; P=0.165) had no significance. Conclusion. The predictive accuracy of any NCCT sign was better than that of sole BHS and SS. Both any NCCT sign and IS were independent predictors of HE. Although IS had higher predictive accuracy, any NCCT sign may still be regarded as a fair predictor of HE when CTA is not available. © 2021 Milind Ratna Shakya et al.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 生物
小类 | 3 区 生物工程与应用微生物 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 生物工程与应用微生物 4 区 医学:研究与实验
JCR分区:
出版当年[2019]版:
Q3 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China [4]Department of Nuclear Medicine, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17067 今日访问量:0 总访问量:916 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院