Signal intensity ratio of draining vein on silent MR angiography as an indicator of high-flow arteriovenous shunt in brain arteriovenous malformation

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, 45# Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China [3]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [4]Center for Evidence-Based Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: Magnetic resonance imaging Magnetic resonance angiography Arteriovenous malformations Brain

摘要:
Objectives To evaluate whether the signal intensity ratio (rSI) of the draining vein on silent MR angiography is correlated with arteriovenous (A-V) transit time on digital subtraction angiography (DSA), thereby identifying high-flow A-V shunt in brain arteriovenous malformation (BAVM), and to analyze whether the rSI and the characteristic of draining veins on silent MRA are associated with hemorrhage presentation. Methods Eighty-one draining veins of 46 participants with BAVM (mean age 33.2 +/- 16.9 years) who underwent silent MRA and DSA were evaluated retrospectively. The correlation between the rSI of the draining vein on silent MRA and A-V transit time on DSA was examined. The AUC-ROC was obtained to evaluate the performance of the rSI in determining the presence of high-flow A-V shunt. The characteristics of draining veins with the maximum rSI (rSImax) were further compared between the hemorrhagic and non-hemorrhagic untreated BAVM. Results The rSI of each draining vein on silent MRA was significantly correlated with A-V transit time from DSA (r = -0.81, p < .001). The AUC-ROC was 0.89 for using the rSI to determine the presence of high-flow A-V shunt. A cut-off rSI value of 1.09 yielded a sensitivity of 82.4% and a specificity of 82.8%. The draining vein with rSImax and no ectasia was significantly more observed in the hemorrhagic group (p = 0.045). Conclusions The rSI of the draining vein on silent MRA is significantly correlated with A-V transit time on DSA, and it can be used as an indicator of high-flow A-V shunt in BAVM.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2019]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, 45# Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
通讯作者:
通讯机构: [1]Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, 45# Changchun Street, Xicheng District, Beijing, China [2]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院