Grey and white matter microstructure changes in epilepsy patients with vagus nerve stimulators.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Beijing Institute of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China
出处:
ISSN:

关键词: Vagus nerve stimulation Epilepsy Diffusion tensor imaging Grey matter White matter

摘要:
Vagus nerve stimulation (VNS) has been widely used as an effective treatment for patients with drug-resistant epilepsy (DRE). However, little is known about grey matter (GM) and white matter (WM) microstructure changes caused by VNS. This study aimed to detect consistent GM and WM alterations in epilepsy patients with vagus nerve stimulators.The diffusion tensor imaging data was acquired from 15 patients who underwent VNS implantation. The voxel-based morphometry (VBM) and tract-based spatial statistics (TBSS) were used to detect group differences in GM and WM microstructure and explore their correlation with postoperative seizure reduction.After 3 months of stimulation, GM density reduced in right cerebellum, left superior temporal gyrus, right inferior temporal gyrus and left thalamus, and increased in left cerebellum, left inferior parietal lobule, left middle occipital gyrus and left gyrus rectus. No significant volume changes had been found in 14 subcortical nuclei. The fractional anisotropy (FA) values reduced in left superior longitudinal fasciculus and left corticospinal tract, and increased in bilateral cingulum and body of corpus callosum. The mean diffusivity (MD) values reduced in right retrolenticular part of internal capsule, right posterior corona radiata and right superior longitudinal fasciculus. The seizure reduction had positive correlation trends with the volume reduction in left nucleus accumbens and right amygdala, and MD reduction in right medial lemniscus and right posterior corona radiata.The results showed that VNS could cause changes of GM density, WM FA and MD values in epilepsy patients. The volume and MD reduction in some subcortical structures might participate in the seizure frequency reduction of VNS.Copyright © 2021 Elsevier B.V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
JCR分区:
出版当年[2019]版:
Q3 SURGERY Q4 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Beijing Institute of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院