Harmonizing Aβ deposition threshold for 18F-florbetaben PET imaging: Addressing discrepancies and calibration between PET/CT and PET/MRI

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Nuclear Medicine/PET Center, Huashan Hospital, Fudan University, Shanghai, China [2]Institute of Biomedical Engineering, School of Medicine, Shanghai University, Shanghai, China [3]Institute of Biomedical Engineering, School of Life Sciences, Shanghai University, Shanghai 200444, China [4]Beijing Sinotau International Pharmaceutical Technology Co., Ltd, Beijing, China [5]Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: 18F-florbetaben PET/CT PET/MRI Cutoff Centiloid

摘要:
Discrepancies between PET/CT and PET/MRI scanners can affect the determination of amyloid beta (Aβ) deposition thresholds in patients with cognitive impairment. This study aimed to identify these differences and propose a calibration method to standardize Aβ quantification across imaging modalities.A total of 133 patients with cognitive impairment underwent Aβ PET imaging and were divided into four groups: a head-to-head PET/CT and PET/MRI cohort (group A, n = 6), an independent PET/CT cohort (group B, n = 48), an independent PET/MRI cohort (group C, n = 79), and another independent PET/MRI cohort (group D, n = 10). Standardized uptake value ratios (SUVR) of global cortical target (CTXsuvr) and centiloid (CL) values were compared within group A and between groups B and C. A whole cerebellum (WC)-referenced SUVR method was used to calibrate CL values in group C, with verification in group D.CTXsuvr values were significantly higher in PET/MRI than in PET/CT in both group A (P < 0.05) and group C versus group B (P < 0.001). Aβ-negative/positive cases showed mean ± variance of CTXsuvr as 1.023 ± 0.104/1.479 ± 0.203 in group B and 1.146 ± 0.100/1.743 ± 0.254 in group C, with cutoffs of 1.140 (CL = 20) and 1.401 (CL = 60), respectively. WC-referenced calibration adjusted PET/MRI cutoff to 1.132 (CL = 19) in group C, aligning it with PET/CT thresholds and validated in group D.WC-referenced SUVR calibration effectively mitigates differences in Aβ thresholds between PET/CT and PET/MRI, enhancing Aβ quantification standardization in multi-modal imaging.© 2025. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
第一作者:
第一作者机构: [1]Department of Nuclear Medicine/PET Center, Huashan Hospital, Fudan University, Shanghai, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17231 今日访问量:0 总访问量:925 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院