Determining the Quantitative Threshold of High-Frequency Oscillation Distribution to Delineate the Epileptogenic Zone by Automated Detection

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Center of Epilepsy, Center for Brain Disorders Research, Capital Medical University, Beijing, China, [2]Center of Epilepsy, Beijing Institute of Brain Disorders, Beijing, China, [3]Neuroelectrophysiological Laboratory, Xuanwu Hospital, Capital Medical University, Beijing, China, [4]College of Electrical and Control Engineering, North China University of Technology, Beijing, China, [5]Department of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China, [6]Department of Neurology, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: HFO automated detection epilepsy surgery threshold

摘要:
Objective: We proposed an improved automated high frequency oscillations (HFOs) detector that could not only be applied to various intracranial electrodes, but also automatically remove false HFOs caused by high-pass filtering. We proposed a continuous resection ratio of high order HFO channels and compared this ratio with each patient's post-surgical outcome, to determine the quantitative threshold of HFO distribution to delineate the epileptogenic zone (EZ). Methods: We enrolled a total of 43 patients diagnosed with refractory epilepsy. The patients were used to optimize the parameters for SEEG electrodes, to test the algorithm for identifying false HFOs, and to calculate the continuous resection ratio of high order HFO channels. The ratio can be used to determine a quantitative threshold to locate the epileptogenic zone. Results: Following optimization, the sensitivity, and specificity of our detector were 66.84 and 73.20% (ripples) and 69.76 and 66.13% (fast ripples, FRs), respectively. The sensitivity and specificity of our algorithm for removing false HFOs were 76.82 and 94.54% (ripples) and 72.55 and 94.87% (FRs), respectively. The median of the continuous resection ratio of high order HFO channels in patients with good surgical outcomes, was significantly higher than in patients with poor outcome, for both ripples and FRs (P < 0.05 ripples and P < 0.001 FRs). Conclusions: Our automated detector has the advantage of not only applying to various intracranial electrodes but also removing false HFOs. Based on the continuous resection ratio of high order HFO channels, we can set the quantitative threshold for locating epileptogenic zones.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 医学
小类 | 3 区 临床神经病学 3 区 神经科学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 神经科学
JCR分区:
出版当年[2016]版:
Q2 CLINICAL NEUROLOGY Q2 NEUROSCIENCES
最新[2023]版:
Q2 CLINICAL NEUROLOGY Q3 NEUROSCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Center of Epilepsy, Center for Brain Disorders Research, Capital Medical University, Beijing, China, [2]Center of Epilepsy, Beijing Institute of Brain Disorders, Beijing, China, [3]Neuroelectrophysiological Laboratory, Xuanwu Hospital, Capital Medical University, Beijing, China,
共同第一作者:
通讯作者:
通讯机构: [1]Center of Epilepsy, Center for Brain Disorders Research, Capital Medical University, Beijing, China, [2]Center of Epilepsy, Beijing Institute of Brain Disorders, Beijing, China, [3]Neuroelectrophysiological Laboratory, Xuanwu Hospital, Capital Medical University, Beijing, China, [5]Department of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China,
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院