当前位置: 首页 > 详情页

Using Real-Time Fusion Imaging Constructed from Contrast-Enhanced Ultrasonography and Magnetic Resonance Imaging for High-Grade Glioma in Neurosurgery

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Departments of Ultrasound,Beijing Tiantan Hospital, Capital Medical University, Dong Cheng District, Beijing, China [2]Departments of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Dong Cheng District, Beijing, China [3]Department of Radiology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
出处:
ISSN:

关键词: Contrast-enhanced ultrasonography Enhanced T1-weighted MRI Fusion imaging High-grade glioma Volume navigation

摘要:
OBJECTIVE: To compare the observation of high-grade glioma (HGG) based on intraoperative multiplane ultrasonography (US) images and preoperative reconstructive coplanar T1-weighted enhanced magnetic resonance imaging (MRI) using volume navigation (V Nav) fusion image technology. METHODS: We retrospectively evaluated intraoperative data obtained from 16 patients diagnosed with HGG (grade III and IV). Overall, 18 nodules observed in 15 patients were examined. HGG images from US and contrast-enhanced US (CEUS) were compared with those from preoperative reconstructive coplanar enhanced T1-weighted MRI using automatic V Nav fusion image technology. RESULTS: All HGG tumors were detected. Images of 13 of 18 tumors (72.2%) with obscure margins using B-mode US were improved with clear tumor boundaries using CEUS imaging. The relative difference in tumor area between CEUS and enhanced MRI modalities in 14 mainly solid component lesions was considered statistically significant (P value < 0.05). There was a perfect correlation of the enhanced area between coplanar CEUS and enhanced MRI. CONCLUSIONS: The V Nav fusion image system combining intraoperative real-time US imaging with reconstructive preoperative coplanar MRI is valuable for imageguided HGG resection. It is suitable for neurosurgeons who lack the expertise in US technology to discern the brain structure and allows better recognition of tumor and edema tissues comparedwith reconstructive preoperative coplanar-enhanced MRI in real time and in multiplane from different angles. In addition, CEUS combined with B-mode US could improve tumor detection and resection control in neurosurgery, even in single US-guided operations.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 医学
小类 | 3 区 外科 4 区 临床神经病学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
JCR分区:
出版当年[2017]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Departments of Ultrasound,Beijing Tiantan Hospital, Capital Medical University, Dong Cheng District, Beijing, China
通讯作者:
通讯机构: [1]Departments of Ultrasound,Beijing Tiantan Hospital, Capital Medical University, Dong Cheng District, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院