Optimal tube voltage for abdominal enhanced CT in children: a self-controlled study

文献详情

资源类型:

收录情况: ◇ SCIE ◇ EI

机构: [1]Department of Radiology, Beijing Children’s Hospital, Capital Medical University, Beijing, PR China [2]Department of Radiology, Fujian Provincial Maternity and Children’s Hospital, Affiliated Hospital of Fujian Medical University, Fujian, PR China [3]Department of Hematology, Beijing Children’s Hospital, Capital Medical University, Beijing, PR China [4]Department of Surgery Oncology, Beijing Children’s Hospital, Capital Medical University, Beijing, PR China
出处:
ISSN:

关键词: abdomen children Computed tomography (CT) low tube voltage radiation dose

摘要:
Background: The use of weight-adapted pediatric computed tomography (CT) tube voltage protocols has been suggested, but a consensus standard has not been established and clinical available studies are not sufficient. Purpose: To determine the best tube voltage for low dose abdominal CT imaging in children. Material and Methods: Eighty-seven cases who needed three CT exams in a 1–3-month interval between scans were enrolled (mean age = 4.69 ± 3.20 years). The three scans were performed with three different tube voltages at 80 kV, 100 kV, and 120 kV, keeping the same radiation dose and same contrast injection protocol. Patients were divided into five groups for analysis based on their body weight. The subjective image quality of the three exams were evaluated using a 4-point scale (4 being the best) for image noise and image quality. The objective evaluation in terms of CT values and standard deviation in aorta, liver, spleen, pancreas, and kidney were measured to calculate the degree of enhancement and contrast-to-noise ratio (CNR) of organs. One-way ANOVA was used to compare the subjective and objective image quality with respect to different tube voltages and different patient weights. Result: The 80-kV tube voltage provided the highest overall enhancement and CNR for the entire patient population and the best objective image quality for the 6.1–28.0 kg subgroup. Conclusion: Patient weight-dependent tube voltage selection maximizes image quality for abdominal enhanced CT in children. The optimal tube voltage for children with weight <28 kg is 80 kV; higher voltages should be selected for children weighing 28.1–50.0 kg. © The Foundation Acta Radiologica 2019.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2017]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Radiology, Beijing Children’s Hospital, Capital Medical University, Beijing, PR China
通讯作者:
通讯机构: [1]Department of Radiology, Beijing Children’s Hospital, Capital Medical University, Beijing, PR China [*1]Beijing Children’s Hospital, Capital Medical University, No. 56, Nanlishi Road, Xicheng District, Beijing 100045, PR China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院