Determination of serum calcium levels by

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [a]National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, 1# Dahua Road, Dongcheng District, Beijing, China [b]Chinese Academy of Medical Sciences, Peking Union Medical College, No. 9 Dongdan Santiao Road, Beijing, 100005, China [c]Department of Clinical Laboratory, Children's Hospital, Capital Institute of Pediatrics, No.2 Yabao Road, Chaoyang District, Beijing, 10020, China [d]National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, No. 1 Dahua Road, Dongcheng District, Beijing, 100730, China [e]National Center for Clinical Laboratories, Beijing Hospital, National Center of Gerontology, Beijing Engineering Research Center of Laboratory Medicine, No. 1 Dahua Road, Dongcheng District, Beijing, 100730, China
出处:
ISSN:

关键词: high accuracy isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) method comparison serum calcium

摘要:
Background: Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China. © 2018 2018 Walter de Gruyter GmbH, Berlin/Boston.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 医学
小类 | 2 区 医学实验技术
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学实验技术
JCR分区:
出版当年[2015]版:
Q1 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q1 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17009 今日访问量:1 总访问量:908 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院