Background: Measurement of optic nerve sheath diameter (ONSD) is a fast and non-invasive method in detecting elevated intracranial pressure. However, the reported normal range of ONSD was inconsistent. The objective of the study was to determine the normal range of ONSD in healthy Chinese adults. Methods: Eyeball transverse diameter (ETD), optic nerve diameter (OND), and ONSD were measured by ultrasound examination in healthy adult volunteers. The OND and ONSD were assessed 3 mm behind the globe. The section showing maximal transverse diameter of the eyeball was frozen and the diameter was measured. Each ETD, OND and ONSD was examined twice and the mean value was calculated. Results: A total of 519 healthy volunteers were included in the study. The median (interquartile range) of ETD, OND and ONSD were 22.3 (21.6 to 23.1) mm, 3.2 (2.9 to 3.4) mm, and 5.1 (4.7 to 5.4) mm, respectively. The 95 % percentile of ONSD was 5.9 mm. There was no significant difference in ETD, OND or ONSD between male and female, or between left and right eye. ONSD was significantly correlated with OND (r = 0.62, P < 0.001), and the median OND/ONSD ratio (interquartile range) was 0.63 (0.59 to 0.67). Conclusions: The median and the 95 % percentile of sonographic measurement of ONSD are 5.1 mm and 5.9 mm in healthy Chinese adults. The ONSD is correlated with OND, while independent of gender, age, height, weight and ETD. The median OND/ONSD ratio is 0.63 and this parameter warrants further investigation in patients with brain injury.
第一作者机构:[1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing 100050, Peoples R China;[2]Fujian Med Univ, Fujian Prov Clin Coll, Surg Intens Care Unit, Fuzhou 350001, Fujian, Peoples R China;
通讯作者:
通讯机构:[1]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, Beijing 100050, Peoples R China;[4]Capital Med Univ, Beijing Tiantan Hosp, Dept Crit Care Med, 6 TiantanXili, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
Chen Han,Ding Gui-Sheng,Zhao Yan-Chun,et al.Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults[J].BMC NEUROLOGY.2015,15(1):-.doi:10.1186/s12883-015-0361-x.
APA:
Chen, Han,Ding, Gui-Sheng,Zhao, Yan-Chun,Yu, Rong-Guo&Zhou, Jian-Xin.(2015).Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults.BMC NEUROLOGY,15,(1)
MLA:
Chen, Han,et al."Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults".BMC NEUROLOGY 15..1(2015):-