当前位置: 首页 > 详情页

Ultrasonographic optic nerve sheath diameter as a noninvasive marker for intracranial hypotension

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Neurology, The Neuroscience Center, The First Hospital of Jilin University, Xinmin Street 71, Changchun 130021, China. [2]Center of Vascular Ultrasonography, Beijing Institute of Brain Disorders [3]Department of Vascular Ultrasonography, Xuanwu Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: intracranial hypotension invasive intracranial pressure optic nerve sheath diameter receiver operating characteristic ultrasound

摘要:
Background: Invasive intracranial pressure (ICP) can result in complications, pain, or even aggravate intracranial hypotension (IH) or headache in patients with IH. Objective: To investigate whether ultrasonographic measurements of optic nerve sheath diameter (ONSD) could serve as a noninvasive IH marker. Methods: Ultrasonographic ONSD was measured prior to lumbar puncture (LP) and ONSD measurements compared to LP's opening pressure. We analyzed correlations between ONSD and ICP and determined the optimal ONSD cut-off point for IH. According to their LP on admission, patients were divided into three groups: IH group, normal ICP group, and elevated ICP group. Correlations between ONSD and ICP were analyzed using Pearson's correlation. A receiver operating characteristic (ROC) curve was generated to determine the optimal cut-off point for IH. Results: In total, 136 subjects (75 men, 55.1% men) were included, and 1088 ONSDs were measured. The ONSD of the IH group (2.96 +/- 0.15 mm) was significantly lower than that of the normal (3.59 +/- 0.33 mm) and elevated ICP groups (4.90 +/- 0.42 mm, p < 0.001). There was a significant difference in ONSD within all groups (p < 0.001), and the differences between the two groups were also statistically significant. ONSD and ICP values were strongly correlated, with an r = 0.952 (95% confidence interval [CI]: 0.924-0.969; p < 0.001). After adjusting for age, diastolic blood pressure, systolic blood pressure, body mass index, waistline, and head circumference, ONSD was positively associated with ICP. ROC curve analysis revealed an area under the curve of 0.990 (95% CI: 0.975-1.000). The ONSD cut-off point for identifying decreased opening pressure on LP was 3.15 mm, with 98.3% sensitivity and 91.7% specificity. Conclusions: Ultrasonographic ONSD may be a noninvasive, valuable, and easy-to-perform bedside technology for evaluating IH.

基金:

基金编号: JLSWSRCZX2021-066

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 临床神经病学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 临床神经病学
JCR分区:
出版当年[2020]版:
Q1 CLINICAL NEUROLOGY
最新[2023]版:
Q1 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of Neurology, The Neuroscience Center, The First Hospital of Jilin University, Xinmin Street 71, Changchun 130021, China.
通讯作者:
通讯机构: [1]Department of Neurology, The Neuroscience Center, The First Hospital of Jilin University, Xinmin Street 71, Changchun 130021, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院