当前位置: 首页 > 详情页

Comparison of Transcranial Color-Coded Real-time Sonography and Contrast-Enhanced Color-Coded Sonography for Detection and Characterization of Intracranial Arteriovenous Malformations

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing 100050, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, Dept Neurosurg, Beijing 100050, Peoples R China; [3]New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA; [4]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, 6 Tiantan Xili, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: contrast-enhanced sonography intracranial arteriovenous malformation transcranial color-coded sonography vascular ultrasound

摘要:
Objectives-To compare the diagnostic value of transcranial color-coded real-time sonography and contrast-enhanced color-coded sonography in detection and characterization of intracranial arteriovenous malformations. Methods-Thirty-one patients highly suspected to have an intracranial arteriovenous malformation were imaged with real-time and contrast-enhanced sonography. With digital subtraction angiography as the reference standard, the ability to detect the malformations and accurately determine their size and location was compared between the two imaging techniques. Results-One cavernous hemangioma and 30 intracranial arteriovenous malformations were imaged with real-time and contrast-enhanced sonography, which were confirmed by angiography. The detectability of contrast-enhanced sonography, especially for optimizing visualization of malformations located in the frontal, parietal, and occipital lobes, was higher than that of real-time sonography, although the overall number of malformations was too small to demonstrate significance. The sizes of the malformations (6 in the frontal lobe, 1 in the parietal lobe, and 1 in the occipital lobe) were underestimated by real-time sonography compared to angiography, whereas there was agreement in the sizes between contrast-enhanced sonography and angiography. The detection rates for the 30 arteriovenous malformations on contrast-enhanced and real-time sonography were 96.7% (29 of 30) and 70.0% (21 of 30), respectively (P = .008). Moreover, contrast-enhanced sonography was significantly superior to real-time sonography for detection of feeding arteries (59.5% [22 of 37] versus 83.7% [31 of 37]; P = .004). Although the feeding arteries showed increased peak systolic and end-diastolic velocities after contrast agent injection, there were no statistically significant differences in the velocities before and after injection. Conclusions-Transcranial contrast-enhanced color-coded sonography is superior to color-coded real-time sonography for detection of intracranial arteriovenous malformations, particularly for lesions located in the frontal, parietal, and occipital lobes of the brain.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 声学 4 区 核医学
JCR分区:
出版当年[2012]版:
Q2 ACOUSTICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Q2 ACOUSTICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing 100050, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing 100050, Peoples R China; [4]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, 6 Tiantan Xili, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题