Determination of the optimal energy level in spectral CT imaging for displaying abdominal vessels in pediatric patients

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Childrens Hosp, Imaging Ctr, Beijing 100045, Peoples R China; [2]Capital Med Univ, Beijing Chaoyang Hosp, Imaging Ctr, Beijing 100020, Peoples R China; [3]Capital Med Univ, Beijing Childrens Hosp, Imaging Ctr, 56 Nanlishi Rd, Beijing 100045, Peoples R China
出处:
ISSN:

关键词: Spectral CT Abdominal vessels Best energy level Low radiation dose

摘要:
Purpose: To determine the optimal energy level in contrast-enhanced spectral CT imaging for displaying abdominal vessels in pediatric patients. Materials and methods: This retrospective study was institutional review board approved. 15 children (8 males and 7 females, age range, 6-15 years, mean age 10.1 +/- 3.1 years) underwent contrast-enhanced spectral CT imaging for diagnosing solid tumors in abdomen and pelvic areas were included. A single contrast-enhanced scan was performed using a dual energy spectral CT mode with a new split contrast injection scheme (iodixanol at 1-1.5 ml/kg dose. 2/3 first, 1/3 at 7-15 s after the first injection). 101 sets of monochromatic images with photon energies of 40-140 keV with 1 keV interval were reconstructed. Contrast-noise-ratio (CNR) for hepatic portal or vein were generated and compared at every energy level to determine the optimal energy level to maximize CNR. 2 board-certified radiologists interpreted the selected image sets independently for image quality scores. Results: CT values and CNR for the vessels increased as photon energy decreased from 140 to 40 keV: (CT value: 48.29-570.12 HU, CNR: 0.08-14.90) in the abdominal aorta, (58.48-369.73 HU, 0.64-5.87) in the inferior vena cava, and (58.48-369.73 HU, 0.06-6.96) in the portal vein. Monochromatic images at 40-50 keV (average 42.0 +/- 4.67 keV) could display vessels above three levels clearly, and with excellent image quality scores of 3.17 +/- 0.58 (of 4) (k = 0.50). The CNR values at the optimal energy level were significantly higher than those at 70 keV, an average energy corresponding to the conventional 120 kVp for abdominal CT imaging. Conclusion: Spectral CT imaging provides a set of monochromatic images to optimize image quality and enhance vascular visibility, especially in the hepatic portal and vein systems. The best CNR for displaying abdominal vessels in children was obtained at 42 keV photon energy level. (C) 2013 Published by Elsevier Ireland Ltd.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2012]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Childrens Hosp, Imaging Ctr, Beijing 100045, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Childrens Hosp, Imaging Ctr, Beijing 100045, Peoples R China; [3]Capital Med Univ, Beijing Childrens Hosp, Imaging Ctr, 56 Nanlishi Rd, Beijing 100045, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院