当前位置: 首页 > 详情页

"Dynamic spot sign" on CT perfusion source images predicts haematoma expansion in acute intracerebral haemorrhage

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Beijing Tiantan Hosp, Dept Neuroradiol, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Chaoyang Hosp, Dept Radiol, Beijing, Peoples R China
出处:
ISSN:

关键词: Computed tomography Perfusion Source images Intracerebral haemorrhage Prognosis

摘要:
To evaluate the association between dynamic progressive enhancing foci ("dynamic spot sign") in acute haematoma on CT perfusion source images (CTP-SI) and haematoma expansion. One hundred twelve consecutive patients with spontaneous intracerebral haemorrhage according to unenhanced CT, CTP and CT angiography within 6 h of symptom onset were prospectively evaluated. Patients were dichotomised according to the presence/absence of the dynamic spot sign on CTP-SI in haematoma. The predictive value of haematoma expansion was analysed. Haematoma expansion was detected in 28 patients (25.0 %) on follow-up unenhanced CT images. Thirty patients (26.8 %) demonstrated the dynamic spot sign on CTP-SI, about 83.3 % of patients with haematoma expansion (P < 0.001). Sensitivity, specificity, positive predictive value, negative predictive value and kappa value for expansion were 89.3 %, 94.0 %, 96.3 %, 83.3 % and 0.814, respectively. In multiple regression, the presence of the CTP dynamic spot sign within acute haematomas independently predicted haematoma expansion; the univariate analysis OR value was 131.667 (29.386-590.289), P < 0.0001. Moreover, the multivariate analysis CTP dynamic spot sign OR value was 203.996 (32.123-1295.488), P < 0.0001. The CTP-SI dynamic spot sign is associated with acute haematoma expansion, is more direct in showing active ongoing bleeding and has a higher predictive value than the CTA spot sign. aEuro cent It is important to identify potential progression of spontaneous intracerebral haemorrhage. aEuro cent Dynamic enhancement within CT perfusion source images is associated with haemorrhage expansion. aEuro cent The CTP dynamic spot sign may be present throughout arterial to venous phase imaging. aEuro cent The CTP dynamic spot sign carries a higher predive value for haematoma expansion than CTA.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2011]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Beijing Tiantan Hosp, Dept Neuroradiol, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Beijing Tiantan Hosp, Dept Neuroradiol, Beijing, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院