当前位置: 首页 > 详情页

Identification of type IV collagen exposure as a molecular imaging target for early detection of thoracic aortic dissection

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Beijing Anzhen Hospital, Capital Medical University,Key Laboratory of Remodeling-Related Cardiovascular Diseases, Ministry of Education,Beijing collaborative innovative research center for cardiovascular diseases,Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029 China [2]Beijing Laboratory of Biomedical Materials, Key Laboratory of Carbon Fiber and Functional Polymers (Beijing University of Chemical Technology), Ministry of Education, Beijing University of Chemical Technology, Beijing 100029 China.
出处:
ISSN:

关键词: Thoracic aortic dissection Early diagnosis Risk prediction Magnetic resonance imaging Fluorescence imaging

摘要:
Thoracic aortic dissection (TAD) is an aggressive and life-threatening vascular disease and there is no effective means of early diagnosis of dissection. Type IV collagen (Col-IV) is a major component of the sub-endothelial basement membrane, which is initially exposed followed by endothelial injury as early-stage event of TAD. So, we want to build a noninvasive diagnostic method to detect early dissection by identifying the exposed Col-IV via MRI. Methods: Col-IV-targeted magnetic resonance/fluorescence dual probe (Col-IV-DOTA-Gd-rhodamine B; CDR) was synthesized by amide reaction and coordination reaction. Flow cytometry analysis was used to evaluate the cell viability of SMC treated with CDR and fluorescence assays were used to assess the Col-IV targeting ability of CDR in vitro. We then examined the sensitivity and specificity of CDR at different stages of TAD via MRI and bioluminescence imaging in vivo. Results: The localization of Col-IV (under the intima) was observed by histology images. CDR bound specifically to Col-IV-expressing vascular smooth muscle cells and BAPN-induced dissected aorta. The CDR signal was co-detected by magnetic resonance imaging (MRI) and bioluminescence imaging as early as 2 weeks after BAPN administration (pre-dissection stage). The ability to detect rupture of dissected aorta was indicated by a strong normalized signal enhancement (NSE) in vivo. Moreover, NSE was negatively correlated with the time of dissection rupture after BAPN administration (r(2) = 0.8482). Conclusion: As confirmed by in vivo studies, the CDR can identify the exposed Col-IV in degenerated aorta to monitor the progress of aortic dissection from the early stage to the rupture via MRI. Thus, CDR-enhanced MRI proposes a potential method for dissection screening, and for monitoring disease progression and therapeutic response.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 1 区 医学
小类 | 1 区 医学:研究与实验
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 医学:研究与实验
JCR分区:
出版当年[2016]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q1 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Beijing Anzhen Hospital, Capital Medical University,Key Laboratory of Remodeling-Related Cardiovascular Diseases, Ministry of Education,Beijing collaborative innovative research center for cardiovascular diseases,Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029 China
共同第一作者:
通讯作者:
通讯机构: [1]Beijing Anzhen Hospital, Capital Medical University,Key Laboratory of Remodeling-Related Cardiovascular Diseases, Ministry of Education,Beijing collaborative innovative research center for cardiovascular diseases,Beijing Institute of Heart Lung and Blood Vessel Diseases, Beijing 100029 China [2]Beijing Laboratory of Biomedical Materials, Key Laboratory of Carbon Fiber and Functional Polymers (Beijing University of Chemical Technology), Ministry of Education, Beijing University of Chemical Technology, Beijing 100029 China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院