当前位置: 首页 > 详情页

Safety and efficacy of catheter ablation of ventricular arrhythmias with para-Hisian origin via a systematic direct approach from the aortic sinus cusp

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China [2]Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China [3]Department of Cardiology, Peking University Third Hospital, Beijing, China.
出处:
ISSN:

关键词: Aortic sinus cusp Catheter ablation Para-Hisian Right ventricle Ventricular arrhythmia

摘要:
BACKGROUND Catheter ablation of ventricular arrhythmias (VAs) originating from the para-Hisian region could be challenging because of a potential damage to atrioventricular conduction system. OBJECTIVE The purpose of this study was to evaluate the safety and efficacy of catheter ablation of VAs originating from the para-Hisian region via a systematic direct approach from aortic sinus cusps (ASCs). METHODS Twenty-one consecutive patients with VAs with para-Hisian origin were included. Electrophysiological mapping of the entire right ventricle was initially performed, and then retrograde ASC mapping was performed when the earliest ventricular activation was recorded in the His bundle region. Ablation was preferentially performed within ASCs in all patients. RESULTS Radiofrequency energy delivery resulted in the elimination of VAs in 17 of 21 patients (81%). In the remaining 4 patients, radiofrequency application was initiated at the target site of the right ventricular septum around the His bundle region and clinical VAs were finally successfully eliminated without junctional rhythm in 2 of 4 patients. During a mean follow-up of 34.8 +/- 11.3 months, 1 of the 19 acute successful patients had VA recurrence. No procedure-related complications occurred during ablation or follow-up. CONCLUSION Catheter ablation of VAs originating from the para-Hisian region via a direct approach from ASCs may be safe and effective in most unselected patients.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 2 区 医学
小类 | 2 区 心脏和心血管系统
最新[2025]版:
大类 | 1 区 医学
小类 | 2 区 心脏和心血管系统
JCR分区:
出版当年[2016]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q1 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China
通讯作者:
通讯机构: [1]State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, China [*1]State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences, Peking Union Medical College, 167 Beilishi Road, Xicheng District, 100037 Beijing
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17319 今日访问量:0 总访问量:932 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院