In vitro and in vivo blood compatibility evaluation of a novel Chinese valved bovine pericardium patch

| 认领 | 导出 |

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Affiliated Anzhen Hosp, Pediat Heart Ctr, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Pediat Heart Ctr, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Blood compatibility bovine pericardium patch congenital heart disease RVOT reconstruction autologous pericardium biological compatibility

摘要:
Researchers over the world are discovering ideal materials with favorable biocompatibility for valved conduits to treat congenital heart disease. Blood compatibility should be fundamentally considered for vascular devices. At present, autologous pericardium shows the best blood compatibility. Therefore, we employed the autologous pericardium as a control (control group) to compare and explore the in vitro and in vivo blood compatibility of a novel Chinese valved bovine pericardium patch with superior fatigue durability and diverse types (treatment group). Both patches were implanted into small fat- tail sheep to replace the antetheca of right ventricular outflow tract (RVOT) and pulmonary trunk through surgery. All animals survived to the predetermined time without any complications. Operation time, cardiopulmonary bypass time, and aortic cross clamp time in the control group were significantly longer than those in the treatment group (P < 0.05). Good healing status in the both planted areas was observed without any thrombosis or infarction. There was no significant difference in In vivo blood compatibility indicators including red blood cells injury, blood routine, and thrombosis which were investigated by free hemoglobin (HGB) determination, automatic blood cell analyzer, and naked eye/microscope observation, respectively (P > 0.05). Results of in vitro compatibility indexes including hemolysis, complement activation, plasma soluble P-selectin, and dynamic clotting which were evaluated through spectrophotometry and ELISA kits were also exactly similar between the two groups (P > 0.05). Therefore, this Chinese patch exhibited wonderful blood compatibility and might be developed as a medical device for RVOT reconstruction.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2015]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2024]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2024版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Affiliated Anzhen Hosp, Pediat Heart Ctr, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Affiliated Anzhen Hosp, Pediat Heart Ctr, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Pediat Heart Ctr, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17708 今日访问量:0 总访问量:943 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院