Improving hemodynamics of cardiovascular system under a novel intraventricular assist device support via modeling and simulations

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Tsinghua Univ, State Key Lab Precis Measurement Technol & Instru, Beijing, Peoples R China; [2]Tsinghua Univ, Grad Sch Shenzhen, Div Adv Mfg, Shenzhen, Peoples R China; [3]Capital Med Univ, Beijing Anzhen Hosp, Cardiac Surg Ctr, Beijing, Peoples R China
出处:
ISSN:

关键词: Cardiovascular system model heart failure hemodynamics iVAD modelling left ventricle assist device

摘要:
Ventricular assist devices (LVADs) are increasingly recognized for supporting blood circulation in heart failure patients who are non-transplant eligible. Because of its volume, the traditional pulsatile device is not easy to implant intracorporeally. Continuous flow LVADs (CF-LVADs) reduce arterial pulsatility and only offer continuous flow, which is different from physiological flow, and may cause long-term complications in the cardiovascular system. The aim of this study was to design a new pulsatile assist device that overcomes this disadvantage, and to test this device in the cardiovascular system. Firstly, the input and output characteristics of the new device were tested in a simple cardiovascular mock system. A detailed mathematical model was established by fitting the experimental data. Secondly, the model was tested in four pathological cases, and was simulated and coupled with a fifth-order cardiovascular system and a new device model using Matlab software. Using assistance of the new device, we demonstrated that the left ventricle pressure, aortic pressure, and aortic flow of heart failure patients improved to the levels of a healthy individual. Especially, in state IV level heart failure patients, the systolic blood pressure increased from 81.34 mmHg to 132.1 mmHg, whereas the diastolic blood pressure increased from 54.28 mmHg to 78.7 mmHg. Cardiac output increased from 3.21 L/min to 5.16 L/min. The newly-developed assist device not only provided a physiological flow that was similar to healthy individuals, but also effectively improved the ability of the pathological ventricular volume. Finally, the effects of the new device on other hemodynamic parameters are discussed.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 外科
JCR分区:
出版当年[2015]版:
最新[2023]版:
Q3 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版]

第一作者:
第一作者机构: [1]Tsinghua Univ, State Key Lab Precis Measurement Technol & Instru, Beijing, Peoples R China; [2]Tsinghua Univ, Grad Sch Shenzhen, Div Adv Mfg, Shenzhen, Peoples R China;
通讯作者:
通讯机构: [1]Tsinghua Univ, State Key Lab Precis Measurement Technol & Instru, Beijing, Peoples R China; [2]Tsinghua Univ, Grad Sch Shenzhen, Div Adv Mfg, Shenzhen, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16936 今日访问量:0 总访问量:903 更新日期:2025-03-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院