MR Elastography (MRE) is a noninvasive technique for measuring tissue stiffness that has been used to assess the average stiffness of the abdominal aorta. The utility of aortic MRE would be improved if it could provide information about local variations in aortic stiffness. We hypothesize that regional variations in aortic stiffness can also be measured with MRE and the purpose of this work was to demonstrate that MRE can measure regional stiffness variations in a vascular phantom and in ex vivo porcine aortas. A vascular phantom was fabricated, containing two silicone tubes embedded in gel. A segment of one of the tubes was modified to increase its stiffness. MRE was performed on the phantom with a continuous flow of water through the tubes. The stiffness distribution along the modified tube was measured and compared to the reference tube. MRE was also performed in porcine aortas embedded in gel with segments treated with saline or formalin for 4 days. The stiffness difference between saline- and formalin-treated aortic segments was measured by MRE and mechanical tests. A positive correlation was found between the regional stiffnesses measured by MRE and mechanical tests. The results indicate that MRE can be used to evaluate the local stiffness distribution in silicone tubes and ex vivo porcine aortas. It may therefore be possible to apply MRE to measure regional stiffness variations of the aorta in vivo. (C) 2015 Elsevier Inc. All rights reserved.
基金:
Natural Science Foundation of ChinaNational Natural Science Foundation of China [81271542]; National Institutes of HealthUnited States Department of Health & Human ServicesNational Institutes of Health (NIH) - USA [EB001981]
第一作者机构:[1]Mayo Clin, Dept Radiol, Rochester, MN 55905 USA;[2]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
通讯作者:
通讯机构:[1]Mayo Clin, Dept Radiol, Rochester, MN 55905 USA;[3]Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
推荐引用方式(GB/T 7714):
Zhang Nan,Chen Jun,Yin Meng,et al.Quantification of regional aortic stiffness using MR elastography: A phantom and ex-vivo porcine aorta study[J].MAGNETIC RESONANCE IMAGING.2016,34(2):91-96.doi:10.1016/j.mri.2015.10.011.
APA:
Zhang, Nan,Chen, Jun,Yin, Meng,Glaser, Kevin J.,Xu, Lei&Ehman, Richard L..(2016).Quantification of regional aortic stiffness using MR elastography: A phantom and ex-vivo porcine aorta study.MAGNETIC RESONANCE IMAGING,34,(2)
MLA:
Zhang, Nan,et al."Quantification of regional aortic stiffness using MR elastography: A phantom and ex-vivo porcine aorta study".MAGNETIC RESONANCE IMAGING 34..2(2016):91-96