当前位置: 首页 > 详情页

Quantification of myocardial delayed enhancement and wall thickness in hypertrophic cardiomyopathy: Multidetector computed tomography versus magnetic resonance imaging

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China; [2]Med Univ Innsbruck, Dept Radiol 2, A-6020 Innsbruck, Austria; [3]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing, Peoples R China
出处:
ISSN:

关键词: Hypertrophic cardiomyopathy Myocardial delayed enhancement MDCT MRI

摘要:
Objectives: To evaluate the accuracy of multidetector computed tomography (MDCT) in assessing myocardial delayed enhancement and left ventricle wall thickness in hypertrophic cardiomyopathy (HCM) compared with cardiac magnetic resonance (CMR) as the reference standard. Materials and methods: Eighty consecutive patients (59 male; 53.2 +/- 13.0 years) were examined with MDCT, followed by CMR 1 day later. Cardiac CT angiography and a delayed CT were performed. CMR was performed according to a standardized protocol. Left ventricle wall thickness and positions of myocardial delayed enhancement were identified in both CMR and CT images according to the American Heart Association left ventricle 17-segment model. Myocardial delayed enhancement was characterized as "dense" (areas with clear defined borders) or "diffuse" and then quantified using both techniques. Results: Left ventricle wall thickness determined by MDCT was significantly correlated with CMR (R = 0.88, P < 0.01). Compared with CMR, MDCT accurately diagnosed 74 of 78 (94.9%) patients and 1243 of 1326 (93.7%) segments. For dense myocardial delayed enhancement, MDCT significantly correlated with CMR (R = 0.88, P < 0.01) and slightly underestimated myocardial delayed enhancement (mean, -3.85%; lower and upper limits of agreement, -13.40% and 5.70%, respectively). Conclusions: MDCT provides reliable quantification of myocardial delayed enhancement and evaluation of left ventricle wall thickness and has a good correlation with CMR in patients with HCM when a comprehensive cardiac CT protocol is used and can be applied for intervention planning. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2012]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China; [3]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院