Continuous noninvasive blood pressure estimation using tissue blood flow measured by diffuse correlation spectroscopy

文献详情

资源类型:
Pubmed体系:
机构: [1]Beijing University of Technology, School of Information Science and Technology, Beijing Key Laboratory of Computational Intelligence and Intelligent System, Beijing, China [2]Beijing Laboratory of Advanced Information Networks, Beijing, China [3]1st Medical Center of Chinese PLA General Hospital, Department of Neurology, Beijing, China [4]Beihang University, School of Engineering Medicine, Beijing Advanced Innovation Center for Biomedical Engineering, Beijing, China [5]Xuanwu Hospital, Capital Medical University, Department of Neurology, Beijing, China [6]Beijing Jishuitan Hospital, Capital Medical University, Burn and Plastic Surgery, Beijing, China [7]China Civil Affairs University, Department of Rehabilitation Engineering, Beijing, China
出处:

摘要:
Blood pressure (BP) is an important parameter of human health, since hypertension is a major risk factor of the cardiovascular system. Nowadays, the continuous measurement of BP is only possible with an invasive measurement method using catheter as the gold standard. Diffuse correlation spectroscopy (DCS) is a powerful tool for assessing microvascular hemodynamics in deep tissues, which can reliably provide a blood flow index whose changes are proportional to relative changes in tissue blood flow (BF). This study presents a new solution that enables to use tissue BF measured by our developed DCS device for continuous BP monitoring via deep learning approach. We evaluated the utility of tissue BF for continuous BP estimation via a proposed BFBP model. In vivo experiments (12 subjects) were performed to collect tissue BF and continuous BP data simultaneously to verify the feasibility of BFBP model. The mean absolute errors of the continuous BP estimates were 5.54 ± 5.03 mm Hg for systolic BP, 1.71 ± 2.86 mm Hg for diastolic BP, indicating that DCS provides a novel way for continuous BP estimation. Moreover, we compared the proposed BFBP model with other models based on an open BP dataset from UC Irvine database. The experimental results indicated that the estimated continuous BP achieves grade A for both systolic blood pressure and diastolic blood pressure according to the British Hypertension Society standard. Ultimately, experimental results show that the proposed method enables feasible continuous estimation of BP using noninvasive tissue BF measured by our developed DCS device based on the proposed BFBP model.© 2025 Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 3 区 医学
小类 | 3 区 工程:生物医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 工程:生物医学
第一作者:
第一作者机构: [1]Beijing University of Technology, School of Information Science and Technology, Beijing Key Laboratory of Computational Intelligence and Intelligent System, Beijing, China [2]Beijing Laboratory of Advanced Information Networks, Beijing, China
通讯作者:
通讯机构: [1]Beijing University of Technology, School of Information Science and Technology, Beijing Key Laboratory of Computational Intelligence and Intelligent System, Beijing, China [2]Beijing Laboratory of Advanced Information Networks, Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:18035 今日访问量:0 总访问量:984 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院