当前位置: 首页 > 详情页

Trigeminal somatosensory-evoked potential: A neurophysiological tool to monitor the extent of lesion of ganglion radiofrequency thermocoagulation in idiopathic trigeminal neuralgia A case-control study

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [a]Department of Pain Management, Xuanwu Hospital of Capital Medical University, Beijing, China. [b]Department of Neurosurgery, Yuquan Hospital, Tsinghua University, Beijing, China.
出处:
ISSN:

关键词: ganglion radiofrequency thermocoagulation trigeminal neuralgia trigeminal somatosensory evoked potential

摘要:
To reflect the extent of thermolesion of ganglion by testing the change of trigeminal somatosensory-evoked potential (TSEP) before and after ganglion radiofrequency thermocoagulation surgery (GRT), and evaluate long-term clinic effect by follow-up visiting of 1 year. Patients with idiopathic trigeminal neuralgia (TN) in the second division were enrolled between October 2014 and October 2015. They were treated with computed tomography-guided GRT and a follow-up visiting of 1 year. Bilateral TSEP measurements were performed 1 day before and 2 days after the GRT surgery. The latency and peak-to-peak amplitude of W2 and W3 were recorded. Immediate postprocedure pain relief (grades I-III) was 100% and 92.5% 1 year later. Facial numbness rate of grades III and IV was 70%, 40%, and 12.5%, respectively, at immediate, 2 days, and 1 year after GRT. No sever complications happened. The latency of W2 and W3 of patients who had no pain no numbness after 1 year of GRT was 1.74 +/- 0.24 and 3.84 +/- 0.66 ms, respectively, of TN side, and 1.71 +/- 0.39 and 3.63 +/- 0.85 ms of the healthy side before GRT. The amplitude of W2 and W3 was 1.13 +/- 0.50 and 1.99 +/- 1.09 uv, respectively, of TN side and 1.24 +/- 0.40 and 1.89 +/- 0.81 uv of the healthy side before GRT. There was no statistical difference of the latency and amplitude between 2 sides of W2 and W3 before surgery (P>0.05). The latency of W2 and W3 delayed and the amplitude reduced especially in TN side after surgery comparing before (P<0.001). And, comparisons of the latency and amplitude of W2 and W3 between TN side and the healthy side after surgery showed the latency of W2 and W3 delayed (W2: P=0.02; W3: P=0.01) and the amplitude of W2 reduced (P=0.003), but the amplitude of W3 had no statistical difference (P=0.22). The mean delayed latency and 95% confident interval of W2 and W3 were 0.22 +/- 0.35 (0.1-0.34) ms and 0.35 +/- 0.64 (0.14-0.57) ms, respectively. The mean decreased amplitude and 95% confident interval of W2 and W3 were 22 +/- 24 (14-30)% and 23 +/- 32 (12-34)%, respectively. GRT can make the latency delay and the amplitude decrease of TSEP. And the latency and amplitude of W2 and W3 can be considered reliable and safe reference for monitoring the extent of thermolesion.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2015]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2024]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2024版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [a]Department of Pain Management, Xuanwu Hospital of Capital Medical University, Beijing, China.
通讯作者:
通讯机构: [*1]Department of Pain Management, Xuanwu Hospital of Capital Medical University, ChangChun Street 45, Beijing 100053, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:18198 今日访问量:0 总访问量:996 更新日期:2025-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院