当前位置: 首页 > 详情页

Monitoring of intracranial venous sinus pressure and prevention for venous air embolism during operation with semi-sitting position

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [a]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [b]International Neuroscience Institute (China-INI), Beijing, China [c]Anesthesiology Department, XuanWu Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

关键词: Intracranial venous sinus pressure Jugular bulb pressure Semi-sitting position Venous air embolism

摘要:
Background: Venous air embolism (VAE) during craniotomy operation with semi-sitting position is closely related to intracranial venous pressure. The objective of current study was to explore the relationship between intracranial venous pressure and VAE during operation with semi-sitting position. Methods: Between April 2018 and January 2019, 25 patients with vestibular schwannoma and 1 patient with posterior fossa meningioma received operation under semi-sitting position. Catheterization at jugular bulb was conducted by puncture of jugular vein with central venous catheter under guidance of ultrasound. The central venous catheter was then connected to a pressure sensor to continuously monitor the jugular bulb pressure (JBP). Both JBP and VAE were continuously monitored during operation to explore the relationship between JBP and intraoperative VAE under semi-sitting position. Results: Under supine position, JBP significantly increased when the head was rotated 45° to the right compared with that recorded at neutral head position. Among all 26 patients, VAE occurred in 4 (15.4%) cases during operation including 2 minor VAE and 2 moderate VAE. Among 3 patients with negative JBP relative to atmosphere pressure, 2 occurred VAE during operation; while only 2 patients occurred VAE among other 23 cases whose JBP was positive relative to atmosphere pressure (P = 0.009). Conclusion: The pressure of intracranial sinus could be continuously monitored by catheterization at jugular bulb. JBP monitoring could be used for prediction of intraoperative VAE. The rate of intraoperative VAE was significantly increased when JBP was negative relative to atmosphere pressure. © 2020 Elsevier Ltd

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 神经科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 神经科学
JCR分区:
出版当年[2018]版:
Q4 CLINICAL NEUROLOGY Q4 NEUROSCIENCES
最新[2024]版:
Q3 CLINICAL NEUROLOGY Q4 NEUROSCIENCES

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [a]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [b]International Neuroscience Institute (China-INI), Beijing, China
通讯作者:
通讯机构: [a]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [b]International Neuroscience Institute (China-INI), Beijing, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:18261 今日访问量:0 总访问量:1004 更新日期:2025-11-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院