An open label, prospective, multicenter, non-interventional study of iodixanol 270 mg I/mL for use in individuals undergoing computed tomography angiography in real-world clinical practice

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, PR China [2]Department of Radiology, Fuwai Hospital, National Center for Cardiovascular Disease, Chinese Academy of Medical Science, Peking Union Medical College, Beijing, PR China [3]Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology,Wuhan, Hubei, PR China [4]Department of Radiology, West China Hospital, Sichuan University, Chengdu, Sichuan, PR China
出处:
ISSN:

关键词: Computed tomography angiography iodixanol image quality radiation dose

摘要:
Background: Concern about radiation exposure is leading to an increasing interest in low-concentration contrast medium administration. Purpose: To evaluate the image quality and safety profile after administration of iodixanol 270 mg I/mL at 100-kVp tube voltage with iterative reconstruction in subjects undergoing computed tomography angiography (CTA). Material and Methods: Patients who completed CTA examination using iodixanol 270 mg I/mL and 100-kVp tube voltage along with iterative reconstruction for coronary, aortic, head and neck, renal, or pulmonary arteries were included. Image quality was qualitatively and quantitatively evaluated. Incidence of adverse events (AEs) and adverse drug reactions (ADRs) within seven days and radiation dose were also analyzed. Results: A total of 4513 individuals in 42 centers in China were enrolled, among which 4367 were included in efficacy analysis. The mean image quality score was 4.8 +/- 0.45 across all arteries (all above 4.6) and 99.7% of the individuals' images were classified as evaluable. The CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the regions of interest (ROIs) were 431.79 +/- 99.018, 18.29 +/- 11.947, and 28.21 +/- 19.535 HU, respectively. Of all the participants, 68 (1.5%) and 65 (1.4%) experienced AEs and ADRs, respectively. No serious AEs or AEs leading to discontinuation occurred. The average effective radiation dose was 3.13 +/- 2.550 mSv. Conclusion: Iodixanol 270 mg I/mL in combination with 100-kVp tube voltage and iterative reconstruction could be safely applied in CTA and yield high-quality and evaluable images with reduced radiation dose.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2017]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, PR China
通讯作者:
通讯机构: [*1]Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing, PR China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院