当前位置: 首页 > 详情页

Experience with thoracic endovascular aortic repair applied in treating Stanford type B aortic dissection: An analysis of 98 cases

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Vascular Surgery, Chengde Medical University Affiliated Hospital, China [2]Department of Vascular Surgery, Xuan Wu Hospital, Capital Medical University, Beijing, China [3]Department of Nephrology, Chengde Medical University Affiliated Hospital, China
出处:
ISSN:

关键词: thoracic endovascular aortic repair Stanford type B aortic dissection clinical value

摘要:
Background. Thoracic endovascular aortic repair (TEVAR) has been frequently applied in Stanford type B aortic dissection since thoracic aortic diseases were first treated with artificial vessels. Objectives. The aim of this study was to analyze the clinical value of TEVAR applied in treating Stanford type B aortic dissection. Material and methods. Between January 2007 and April 2014, 167 consecutive Stanford type B aortic dissection patients were treated with TEVAR and retrospectively analyzed. Results. All patients had a successful operation. A total of 98 patients were followed-up and the duration of the follow-up ranged from 3 to 63 months with a mean of 25.6 +/- 8.4 months. Proximal type I endoleak occurred in 18 patients with an incidence rate of 18.37% and a cuff was deployed in 7 patients, in whom the endoleak disappeared after 3 months. Two patients died in the perioperative period: one died from aortic dissection rupture, while the other died from infectious shock. One patient died from acute myocardial infarction during the follow-up period. Tears occurred in the end piece of stent grafts in 12 patients, and additional TEVAR was performed. One patient had a proximal retrograde type A dissection; the patient was in an acceptable state of health apart from persistent chest and back pain, and is still in follow-up. Spinal cord ischemia, stent displacement and collapse did not occur. Conclusions. TEVAR is reliable and safe, and it can be widely applied in treating Stanford type B aortic dissection.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2016]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Department of Vascular Surgery, Chengde Medical University Affiliated Hospital, China
通讯作者:
通讯机构: [1]Department of Vascular Surgery, Chengde Medical University Affiliated Hospital, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院