当前位置: 首页 > 详情页

Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Vascular Surgery, Xuan Wu Hospital and Institute of Vascular Surgery, Capital Medical University, Beijing 100053, P.R. China [2]Central Laboratory, Xuan Wu Hospital, Capital Medical University, Beijing 100053, P.R. China
出处:
ISSN:

关键词: renal artery stenosis renin-angiotensin-aldosterone system renovascular hypertension rat model plasma renin activity

摘要:
The aim of the present study was to establish and evaluate a novel and reversible two-kidney, one-clip renovascular hypertensive rat model with a titanium vascular clip. A total of 40 male Sprague-Dawley rats were evenly and randomly divided into a sham-operated group, and 3, 7, 12 and 28D groups (namely removing the vascular clip in the renovascular hypertensive model after 3, 7, 12 and 28 days, respectively). The systolic blood pressure (SBP) and plasma renin activity (PRA) were measured, and color duplex imaging was conducted before placing the clips, as well as before and after removing them. After placing the vascular clips, SBP and PRA in the 3, 7, 12 and 28D groups were significantly increased (SBP: Sham-operated vs. 3D groups, P=0.020; 3 vs. 7D groups, P=0.008; 7 vs. 28D groups, P=0.019; 12 vs. 28D groups, P=0.039, and between other groups P<0.001. PRA: 3 vs. 7D groups, P=0.001; 7 vs. 12D groups, P=0.004; 12 vs. 28D groups, P=0.040, and between other groups, P<0.001). After removing the clips, SBP were significantly reduced in the 3 and 7D groups (P=0.023, 0.040, 0.066 and 0.314 in the 3, 7, 12 and 28D groups, respectively), but were still significantly higher than that before placing clips in the 7, 12 and 28D groups (P=0.067, P=0.005, P<0.001 and P<0.001 in the 3, 7, 12 and 28D groups, respectively). After removing the clips, PRA was significantly reduced in each group (P<0.001, P<0.001, P=0.012 and P=0.049 in 3, 7, 12 and 28D groups, respectively), but still higher than that before placing the clips (P<0.001, P=0.001, P=0.001 and P=0.003 in 3, 7, 12 and 28D groups, respectively). Vascular imaging also indicates this model has a reversible property. In conclusion, a reversible renovascular hypertension rat model is feasible, and provides a basis for research on clinical ischemic nephropathy and renal artery revascularization.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2015]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2024]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2024版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Department of Vascular Surgery, Xuan Wu Hospital and Institute of Vascular Surgery, Capital Medical University, Beijing 100053, P.R. China
通讯作者:
通讯机构: [*1]Department of Vascular Surgery, Xuan Wu Hospital and Institute of Vascular Surgery, Capital Medical University, 45 Changchun Street, Beijing 100053, P.R. China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17670 今日访问量:0 总访问量:939 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院