当前位置: 首页 > 详情页

Percutaneous transluminal renal angioplasty with stent is effective for blood pressure control and renal function improvement in atherosclerotic renal artery stenosis patients

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Department of Vascular Surgery, Chao- Yang Hospital, CapitalMedical University, Beijing 100020, China [2]Department of Vascular Surgery, Xuanwu Hospital, Institute ofVascular Surgery, Capital Medical University, Beijing 100053,China
出处:
ISSN:

关键词: renal artery stenosis renal angioplasty stent renovascular hypertension glomerular filtration rate

摘要:
Background Percutaneous transluminal renal angioplasty with stent is an effective procedure for atherosclerotic renal artery stenosis. However, the decision to perform this procedure has recently raised considerable debate. The aim of this study was to assess the effects of percutaneous transluminal renal angioplasty with stent in atherosclerotic renal artery stenosis patients, especially as it relates to blood pressure control and renal function improvement. Methods A retrospective analysis was made of the clinical data from 125 atherosclerotic renal artery stenosis patients who underwent percutaneous transluminal renal angioplasty from July 2004 to June 2008 in the Department of Vascular Surgery of Beijing Chaoyang Hospital. We compared blood pressure, number of oral antihypertensive medications, and renal function changes pre and post-procedure at 24 months follow-up. Results A total of 125 atherosclerotic renal artery stenosis patients underwent percutaneous transluminal renal angioplasty and 143 stents were placed. At 24 months follow-up, both systolic and diastolic blood pressure and the number of oral antihypertensive medications were significantly reduced (P <0.05). Overall, the estimated glomerular filtration rate did not change significantly (P >0.05); however, a significant increase in estimated glomerular filtration rate was observed in the subgroup of patients with a lower baseline estimated glomerular filtration rate and in the subgroup of patients with bilateral renal artery stenosis (P<0.05). Conclusion Percutaneous transluminal renal angioplasty is a safe procedure for atherosclerotic renal artery stenosis patients, providing a significant improvement in blood pressure control and reduction in the number of oral antihypertensive medications. Chin Med J 2012;125(8):1363-1368

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2010]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Department of Vascular Surgery, Chao- Yang Hospital, CapitalMedical University, Beijing 100020, China [2]Department of Vascular Surgery, Xuanwu Hospital, Institute ofVascular Surgery, Capital Medical University, Beijing 100053,China
通讯作者:
通讯机构: [*1]Department of Vascular Surgery,Xuanwu Hospital,Institute of Vascular Surgery,Capital Medical University,Beijing 100053,China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院