机构:[1]Department of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.[2]Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.[3]MR R&D, Siemens Healthcare, Los Angeles, California, USA.[4]Xuanwu Hospital, Capital Medical University, Beijing, China.首都医科大学宣武医院放射科[5]University of California, Los Angeles, California, USA.
PurposeTo achieve whole-heart coronary magnetic resonance angiography (MRA) with (1.0 mm)(3) spatial resolution and 5 min of free-breathing scan time. MethodsWe used an electrocardiograph-gated, T2-prepared and fat-saturated balanced steady state free precession sequence with 3DPR trajectory for free-breathing data acquisition with 100% gating efficiency. For image reconstruction, we used a self-calibrating iterative SENSE scheme with integrated retrospective motion correction. We performed healthy volunteer study to compare the proposed method with motion-corrected gridding at different retrospective undersampling levels on apparent signal-to-noise ratio (aSNR) and subjective coronary artery (CA) visualization scores. ResultsCompared with gridding, the proposed method significantly improved both image quality metrics for undersampled datasets with 6000, 8000, and 10,000 projections. With as few as 10,000 projections, the proposed method yielded good CA visualization scores (3.02 of 4) and aSNR values comparable to those with 20,000 projections. ConclusionUsing the proposed method, good image quality was observed for free breathing whole-heart coronary MRA at (1.0 mm)(3) resolution with an achievable scan time of 5 min. Magn Reson Med 73:284-291, 2015. (c) 2014 Wiley Periodicals, Inc.
基金:
NIH; (Grant number: HL38698, EB002623);
National Natural Science Foundation of China; (Grant number: 81229001)
第一作者机构:[1]Department of Radiology and Biomedical Engineering, Northwestern University, Chicago, Illinois, USA.[2]Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California, USA.
通讯作者:
通讯机构:[*1]Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, 8700 Beverly Blvd, PACT Suite 800, Los Angeles, CA, USA 90048
推荐引用方式(GB/T 7714):
Jianing Pang ,Behzad Sharif ,Reza Arsanjani ,et al.Accelerated Whole-Heart Coronary MRA Using Motion-Corrected Sensitivity Encoding with Three-Dimensional Projection Reconstruction[J].MAGNETIC RESONANCE IN MEDICINE.2015,73(1):284-291.doi:10.1002/mrm.25097.
APA:
Jianing Pang,,Behzad Sharif,,Reza Arsanjani,,Xiaoming Bi,,Zhaoyang Fan,...&Debiao Li.(2015).Accelerated Whole-Heart Coronary MRA Using Motion-Corrected Sensitivity Encoding with Three-Dimensional Projection Reconstruction.MAGNETIC RESONANCE IN MEDICINE,73,(1)
MLA:
Jianing Pang,,et al."Accelerated Whole-Heart Coronary MRA Using Motion-Corrected Sensitivity Encoding with Three-Dimensional Projection Reconstruction".MAGNETIC RESONANCE IN MEDICINE 73..1(2015):284-291