Ultrasound facilitates identification of combined spinal-epidural puncture in obese parturients

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Department of Anesthesiology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China
出处:
ISSN:

关键词: anesthesia obesity pregnancy caesarean section ultrasound

摘要:
Background The palpation method is widely used in clinical practice to identify the puncture site of combined spinal-epidural (CSE) blocks, but it is usually difficult to accurately locate the puncture site in obese parturients. Accurate identification of the puncture site is crucial for successful CSE block. The objective of this study was to evaluate the impact of ultrasound imaging on the success rate of CSE puncture in obese parturients. Methods Sixty obese parturients with a body mass index >= 30 kg/m(2) who were scheduled for caesarean section were randomized into two equal-sized groups for location of the puncture site: an ultrasound group and a palpation group. The success rate of puncture at the first puncture site, the number of puncture attempts, duration of CSE procedure, time taken to determine the puncture site, and the depth of the epidural space were compared between groups. The frequencies of complications such as puncture site hemorrhage, neurological damage, and inadvertent dural puncture were also studied. Results There were no differences in age, body weight, height, body mass index, or gestational age between the two groups. The success rate of puncture at the first puncture site was significantly higher in the ultrasound group than the palpation group (100.00% vs. 70.00%, P=0.004). The number of puncture attempts was significantly lower in the ultrasound group than the palpation group (chi(2)=6.708, P=0.035). The time taken for determining the puncture site was (0.30 +/- 0.12) minutes in the palpation group and (2.60 +/- 0.61) minutes in the ultrasound group (P<0.001). The duration of CSE procedure was (7.67 +/- 1.52) minutes in the palpation group and (9.37 +/- 1.35) minutes in the ultrasound group (P<0.001). The depth of the epidural space was similar in both groups (P=0.586). Puncture site hemorrhage was observed in 6 (20.00%) patients in the palpation group and 2 (6.67%) patients in the ultrasound group (P=0.255). Conclusions Ultrasound imaging improves the rate of successful puncture at the first puncture site and decreases the number of puncture attempts. It facilitates CSE puncture in obese parturients. Chin Med J 2012;125(21):3840-3843

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2010]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Department of Anesthesiology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China
通讯作者:
通讯机构: [1]Department of Anesthesiology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17070 今日访问量:0 总访问量:919 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院