当前位置: 首页 > 详情页

Multiphase-computed tomography-based target volume definition in conventional fractionated radiotherapy of lung tumors: dosimetric and reliable comparison with the technique using addition of generic margins.

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Department of Radiation Oncology, Second Affiliated Hospital of Soochow University, Suzhou [2]Department of Radiation Oncology, Changshu Affiliated Hospital of Soochow University, Suzhou, China
出处:
ISSN:

关键词: conventional radiotherapy internal target volume lung neoplasm tumor motion

摘要:
The aim of the present study was to compare radiotherapeutic plans based on internal target volume determined by between multiphase computed tomography and addition of a generic margin in lung tumors and to evaluate the reliability of ITV determined by multiphase computed tomography during conventional fractionated radiotherapy. The radiotherapeutic plans based on internal target volume determined by between multiphase computed tomography and addition of a generic margin in 10 patients with lung tumors were applied. The difference of two planning target volumes (PTV) and irradiated dose and volume of normal lung tissue were compared. Weekly new targets were delineated on repeated computed tomography scans, and weekly dose coverage of clinical target volume under two different treatment plans was evaluated. For all patients, PTV3CT volume based on multiphase computed tomography was significantly smaller than that of PTVcon based on addition of a generic margin (t = 6.831, P <0.001). The volume receiving more than 20 Gy in Plan3CT and Plancon was 16.7 ± 5.2% and 20.0 ± 5.2% (t = 7.565, P <0.001), the volume receiving more than 5 Gy was 36.6 ± 7.2% and 42.7 ± 6.4% (t = 7.459, P <0.001), and mean lung dose was 1037.5 ± 275.0 cGy and 1246.8 ± 271.0 cGy (t = 8.078, P <0.001), respectively. Both Plan3CT and Plancon provided a satisfactory clinical target volume coverage weekly during conventional fractionated radiotherapy for 6-7 weeks, and the ratio of the volume receiving the prescription dose was 1.03 ± 0.02 and 1.04 ± 0.02, respectively. The radiotherapeutic plan based on internal target volume determined by multiphase computed tomography can ensure weekly target coverage during conventional fractionated radiotherapy in lung tumors, and it is better than the plan based on the addition of generic internal target volume, which can effectively reduce normal lung tissue irradiation.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 肿瘤学
JCR分区:
出版当年[2009]版:
Q4 ONCOLOGY
最新[2023]版:
Q3 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2009版] 出版当年五年平均 出版前一年[2008版] 出版后一年[2010版]

第一作者:
第一作者机构: [1]Department of Radiation Oncology, Second Affiliated Hospital of Soochow University, Suzhou [2]Department of Radiation Oncology, Changshu Affiliated Hospital of Soochow University, Suzhou, China
通讯作者:
通讯机构: [*1]Department of Radiation Oncology, Second Affiliated Hospital of Soochow University, 1055 Sanxiang Road, Suzhou 215004, Jiangsu Province, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17292 今日访问量:0 总访问量:929 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院