ObjectivesThe computed tomography angiography (CTA) spot sign is a validated predictor of haematoma expansion (HE) in spontaneous intracerebral haemorrhage (SICH). We investigated whether defining the iodine concentration (IC) inside the spot sign and the haematoma on Gemstone spectral imaging (GSI) would improve its sensitivity and specificity for predicting HE.MethodsFrom 2014 to 2016, we prospectively enrolled 65 SICH patients who underwent single-phase spectral CTA within 6 h. Logistic regression was performed to assess the risk factors for HE. The predictive performance of individual spot sign characteristics was examined via receiver operating characteristic (ROC) analysis.ResultsThe spot sign was detected in 46.1% (30/65) of patients. ROC analysis indicated that IC inside the spot sign had the greatest area under the ROC curve for HE (0.858; 95% confidence interval, 0.727-0.989; p = 0.003). Multivariate analysis found that spot sign with higher IC (i.e. IC > 7.82 100 g/ml) was an independent predictor of HE (odds ratio = 34.27; 95% confidence interval, 5.608-209.41; p < 0.001) with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 0.81, 0.75, 0.90 and 0.60, respectively; while the spot sign showed sensitivity, specificity, PPV and NPV of 0.81, 0.79, 0.73 and 0.86. Logistic regression analysis indicated that the IC in haematomas was independently associated with HE (odds ratio = 1.525; 95% confidence interval, 1.041-2.235; p = 0.030).ConclusionsICs in haematoma and in spot sign were all independently associated with HE. IC analysis in spectral imaging may help to identify SICH patients for targeted haemostatic therapy.Key Points center dot Iodine concentration in spot sign and haematoma can predict haematoma expansion center dot Spectral imaging could measure the IC inside the spot sign and haematoma center dot IC in spot sign improved the positive predictive value (PPV) cf. CTA
基金:
Beijing Municipal Natural Science FoundationBeijing Natural Science Foundation
第一作者机构:[1]Neuroradiology Department, Beijing Tiantan Hospital, Capital Medical University, No.6 Tiantan Xili, Dongcheng District, Beijing 100050, China
通讯作者:
通讯机构:[2]Neuroradiology Department, Beijing Neurosurgical Institute, No.6 Tiantan Xili, Dongcheng District, Beijing 100050, China
推荐引用方式(GB/T 7714):
Fu Fan,Sun Shengjun,Liu Liping,et al.Iodine concentration: a new, important characteristic of the spot sign that predicts haematoma expansion[J].EUROPEAN RADIOLOGY.2018,28(10):4343-4349.doi:10.1007/s00330-018-5415-1.
APA:
Fu, Fan,Sun, Shengjun,Liu, Liping,Li, Jianying,Su, Yaping&Li, Yingying.(2018).Iodine concentration: a new, important characteristic of the spot sign that predicts haematoma expansion.EUROPEAN RADIOLOGY,28,(10)
MLA:
Fu, Fan,et al."Iodine concentration: a new, important characteristic of the spot sign that predicts haematoma expansion".EUROPEAN RADIOLOGY 28..10(2018):4343-4349