当前位置: 首页 > 详情页

Different predictivity of fluid responsiveness by pulse pressure variation in children after surgical repair of ventricular septal defect or tetralogy of Fallot

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [a]Department of Anesthesiology, Capital Institute of Pediatrics affiliated Children's Hospital, Beijing, China [b]Anesthesia Center, Capital Medical University affiliated Beijing Anzhen Hospital, Beijing, China [c]Department of Cardiac Surgery, Capital Institute of Pediatrics affiliated Children's Hospital, Beijing, China [d]Clinical Physiology Laboratory, Capital Institute of Pediatrics, Beijing, China
出处:
ISSN:

关键词: cardiac surgery congenital heart disease fluid responsiveness pulse pressure variation

摘要:
Background: Pulse pressure variation derived from the varied pulse contour method is based on heart-lung interaction during mechanical ventilation. It has been shown that pulse pressure variation is predictive of fluid responsiveness in children undergoing surgical repair of ventricular septal defect. Right ventricle compliance and pulmonary vascular capacitance in children with tetralogy of Fallot are underdeveloped as compared to those in ventricular septal defect. We hypothesized that the difference in the right ventricle-pulmonary circulation in the two groups of children would affect the heart-lung interaction and therefore pulse pressure variation predictivity of fluid responsiveness following cardiac surgery. Methods: Infants undergoing complete repair of ventricular septal defect (n=38, 1.05±0.75 years) and tetralogy of Fallot (n=36, 1.15±0.68 years) clinically presenting with low cardiac output were enrolled. Fluid infusion with 5% albumin or fresh frozen plasma was administered. Pulse pressure variation was recorded using pressure recording analytical method along with cardiac index before and after fluid infusion. Patients were considered as responders to fluid loading when cardiac index increased ≥15%. Receiver operating characteristic curves analysis was used to assess the accuracy and cutoffs of pulse pressure variation to predict fluid responsiveness. Results: The pulse pressure variation values before and after fluid infusion were lower in tetralogy of Fallot children than those in ventricular septal defect children (15.2±4.4% vs 19.3±4.4%, P<.001; 11.6±3.8 vs 15.4±4.3%, P<.001, respectively). In ventricular septal defect children, 27 were responders and 11 nonresponders. Receiver operating characteristic curve area was 0.89 (95% confidence interval, 0.77-1.01) and cutoff value 17.4% with a sensitivity of 0.89 and a specificity of 0.91. In tetralogy of Fallot children, 26 were responders and 10 were nonresponders. Receiver operating characteristic curve area was 0.79 (95% CI, 0.64-0.94) and cutoff value 13.4% with a sensitivity of 0.81 and a specificity of 0.80. Conclusion: Pulse pressure variation is predictive of fluid responsiveness in ventricular septal defect and tetralogy of Fallot patients following cardiac surgery. © 2017 John Wiley & Sons Ltd

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 3 区 儿科 4 区 麻醉学
最新[2023]版:
大类 | 4 区 医学
小类 | 3 区 儿科 4 区 麻醉学
JCR分区:
出版当年[2015]版:
Q2 ANESTHESIOLOGY Q2 PEDIATRICS
最新[2023]版:
Q2 ANESTHESIOLOGY Q2 PEDIATRICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院