Extraction of a migrated coil from the Enterprise stent strut using a Solitaire AB stent

文献详情

资源类型:
机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Intervent Neuroradiol Dept, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, Beijing, Peoples R China; [3]Beijing Neurosurg Inst, 6 Tiantan Xili, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: Coil migration embolisation intracranial aneurysm Solitaire AB stent

摘要:
A 56-year-old woman was admitted to stent-assisted coiling for a 2-mm A1 aneurysm of the left anterior cerebral artery and a left 3-mm internal carotid artery aneurysm. While coiling the A1 aneurysm, the first 2 mm x 20 mm coil migrated through the 4.5 mm x 37 mm Enterprise stent struts, lodging at the distal anterior cerebral artery. A 4 mm x 15 mm Solitaire AB stent was used successfully in this case to remove the displaced coil. The A1 aneurysm was re-treated with a 2 mm x 40 mm coil after placement of the Enterprise stent, and the ophthalmic ICA aneurysm was also coiled through the stent struts. The patient was neurologically intact after treatment.

语种:
WOS:
PubmedID:
第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Intervent Neuroradiol Dept, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, Beijing, Peoples R China; [3]Beijing Neurosurg Inst, 6 Tiantan Xili, Beijing 100050, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Neurosurg Inst, Intervent Neuroradiol Dept, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Tiantan Hosp, Beijing, Peoples R China; [3]Beijing Neurosurg Inst, 6 Tiantan Xili, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院