Echo-Tracking Method Improves the Reliability in Flow-Mediated Dilation Assessment by Measuring Brachial Artery Reactivity

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing, Peoples R China; [2]Mil Gen Hosp Beijing, Dept Ultrasound, Beijing 100083, Peoples R China
出处:
ISSN:

关键词: ultrasound echo-tracking B-mode flow-mediated dilation

摘要:
The purpose of the study was to compare the intraobserver and interobserver reliability and agreement for measurement of flow-mediated dilation (FMD) between B-mode method and echo-tracking (ET) method. Twenty healthy volunteers (mean age, 31.6 +/- 9.2 years) underwent ultrasound examination by both B-mode and ET methods. Baseline brachial artery diameter, post-cuff release diameter, and FMD percent were assessed by each sonologist on 2 consecutive days. Reliability was assessed by intraclass correlation coefficients, and Bland-Altman plots were used to visually compare measurement bias and agreement by the 2 ultrasound methods. A total of 40 pairs of data were available for analysis. Excellent intraobserver and interobserver reliability values were found for all variables assessed by the 2 methods. The intraclass correlation coefficient values were higher for ET in both intraobserver and interobserver evaluations, but only for interobserver evaluations for post-cuff release diameter and FMD was there no overlap in the 95% confidence interval. The Bland-Altman plots showed that in 95% of the measurements, the percentage difference between ET and B-mode ultrasound techniques was within 18.1%, 19.4%, and 17.3% for baseline brachial artery diameter, post-cuff release diameter, and FMD percent, respectively. The results suggest that ET and B-mode methods are reproducible in assessing the FMD. The ET method improves the reliability of FMD assessment, but we cannot determine which measurement is better for FMD.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2013]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing, Peoples R China;
通讯作者:
通讯机构: [2]Mil Gen Hosp Beijing, Dept Ultrasound, Beijing 100083, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院