当前位置: 首页 > 详情页

A geometric scaling model for assessing the impact of aneurysm size ratio on hemodynamic characteristics

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Sch Biomed Engn, Beijing 100069, Peoples R China; [2]Beijing Tiantan Hosp, Beijing Neurosurg Inst, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: Intracranial aneurysm Scaled models Aneurysm Size Ratio Hemodynamics

摘要:
Background: The intracranial aneurysm (IA) size has been proved to have impacts on the hemodynamics and can be applied for the prediction of IA rupture risk. Although the relationship between aspect ratio and hemodynamic parameters was investigated using real patients and virtual models, few studies focused on longitudinal experiments of IAs based on patient-specific aneurysm models. We attempted to do longitudinal simulation experiments of IAs by developing a series of scaled models. Methods: In this work, a novel scaling approach was proposed to create IA models with different aneurysm size ratios (ASRs) defined as IA height divided by average neck diameter from a patient-specific aneurysm model and the relationship between the ASR and hemodynamics was explored based on a simulated longitudinal experiment. Wall shear stress, flow patterns and vessel wall displacement were computed from these models. Pearson correlation analysis was performed to elucidate the relationship between the ASR and wall shear stress. The correlation of the ASR and flow velocity was also computed and analyzed. Results: The experiment results showed that there was a significant increase in IA area exposed to low WSS once the ASR > 0.7, and the flow became slower and the blood was more difficult to flow into the aneurysm as the ASR increased. Meanwhile, the results also indicated that average blood flow velocity and WSS had strongly negative correlations with the ASR (r = -0.938 and -0.925, respectively). A narrower impingement region and a more concentrated inflow jet appeared as the ASR increased, and the large local deformation at aneurysm apex could be found as the ASR > 1.7 or 0.7 < the ASR < 1.0. Conclusion: Hemodynamic characteristics varied with the ASR. Besides, it is helpful to further explore the relationship between morphologies and hemodynamics based on a longitudinal simulation by building a series of patient-specific aneurysm scaled models applying our proposed IA scaling algorithm.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 3 区 工程技术
小类 | 4 区 工程:生物医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 工程:生物医学
JCR分区:
出版当年[2012]版:
Q2 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Capital Med Univ, Sch Biomed Engn, Beijing 100069, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Sch Biomed Engn, Beijing 100069, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:17010 今日访问量:0 总访问量:909 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院