机构: [1]Capital Med Univ, Core Lab Clin Med Res, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [2]Capital Med Univ, Dept Clin Lab Diag, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [3]Beijing Key Lab Translat Med Cerebrovasc Dis, Beijing, Peoples R China; [4]Washington Univ, Sch Med, Genome Technol Access Ctr, St Louis, MO USA; [5]Shanghai Tellgen Life Sci Co Ltd, Shanghai, Peoples R China; [6]Capital Med Univ, Core Lab Clin Med Res, Beijing Tiantan Hosp, 6 Tiantan Xili, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: Hook effect Heterophile antibody Immunoassay Multiplex suspension bead array Tumor marker

摘要:
Background: A variety of immunoassays including multiplex suspension bead array have been developed for tumor marker detections; however, these assays could be compromised in their sensitivity and specificity by well-known heterophile antibody interference and hook effect. Methods: Using Luminex (R) multiplex suspension bead arrays, we modified protocols with two newly-developed solutions that can identify heterophile antibody interference and AFP hook effect. Effectiveness of the two solutions was assessed in serum samples from patients. Results: Concentrations of 9 tumor markers in heterophile antibody positive samples assayed with Solution A, containing murine monoclonal antibodies and mouse serum, were significantly reduced when compared with those false high signals assayed without Solution A (all p < 0.01). With incorporation of Solution H (fluorescent beads linked with AFP antigen),a new strategy for identification of AFP hook effect was established, and with this strategy AFP hook effect was identified effectively in serum samples with very high levels of AFP. Conclusions: Two proprietary solutions improve the identification of heterophile antibody interference and AFP hook effect. With these solutions, multiplex suspension bead arrays provide more reliable testing results in tumor marker detection where complex clinical serum samples are used. (C) 2013 Elsevier B.V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 3 区 医学
小类 | 2 区 医学实验技术
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2011]版:
Q1 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Capital Med Univ, Core Lab Clin Med Res, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [2]Capital Med Univ, Dept Clin Lab Diag, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [3]Beijing Key Lab Translat Med Cerebrovasc Dis, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Core Lab Clin Med Res, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [2]Capital Med Univ, Dept Clin Lab Diag, Beijing Tiantan Hosp, Beijing 100050, Peoples R China; [3]Beijing Key Lab Translat Med Cerebrovasc Dis, Beijing, Peoples R China; [6]Capital Med Univ, Core Lab Clin Med Res, Beijing Tiantan Hosp, 6 Tiantan Xili, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院