当前位置: 首页 > 详情页

Compressed sensing based simultaneous black- and gray-blood carotid vessel wall MR imaging

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]First Hosp Nanchang City, Ctr Lab, Nanchang 330008, Jiangxi, Peoples R China; [2]Nanchang Univ, Affiliated Hosp 3, Dept Radiol, Nanchang 330008, Jiangxi, Peoples R China; [3]Univ Cambridge, Dept Radiol, Cambridge CB2 0QQ, England; [4]Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China; [5]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [6]Peking Univ, Coll Engn, Beijing 100871, Peoples R China
出处:
ISSN:

关键词: Compressed sensing Simultaneous three dimensional dual-contrast imaging Gray-blood imaging CS-siBLAG Pseudo-centric phase encoding order Vessel wall imaging

摘要:
Objective: In this study, we sought to demonstrate the blood suppression performance, image quality and morphological measurements for compressed sensing (CS) based simultaneous 3D black- and gray-blood imaging sequence (CS-siBLAG) in carotid vessel wall MR imaging. Materials and methods: Seven healthy volunteers and five patients were recruited. Healthy subjects underwent five CS-siBLAG scans with 1, 2, 3, 4 and 5-fold accelerations. Signal-to-tissue ratio (STR) and contrast-to-tissue ratio (CTR) were computed as the measures of flowing signal suppression performance and the image quality for black-blood imaging of the technique. Vessel lumen area (LA) and wall area (WA) were compared between fully sampled acquisition and each accelerated acquisition. Patients underwent three CS-siBLAG scans with 1, 3 and 5-fold accelerations as well as a 3D time of flight (3D TOF) scan. Two radiologists reviewed the under-sampled black- and gray-blood image quality. Results: STR and CTR values obtained with 2 to 5-fold accelerations were not significantly different from those with full acquisition. LA and WA measured at 2 x, 3 x, 4x and 5 x were all highly correlated to the corresponding values at 1 x. For patients imaging, two radiologists both found that the dual-contrast images at 3 x acceleration exhibited comparable image quality to that of the fully sampled acquisition, and that the images at 5 x exhibited slightly blurred vessel wall and outer vessel wall boundaries. Conclusion: By combining the CS under-sampling pattern and reconstruction, pseudo-centric phase encoding order and dual blood contrast sequences, this technique provides spatially registered black- and gray-blood images and excellent visualization for vessel wall imaging and gray-blood imaging in a short scan time. (C) 2017 Elsevier Inc. All rights reserved.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2015]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]First Hosp Nanchang City, Ctr Lab, Nanchang 330008, Jiangxi, Peoples R China; [2]Nanchang Univ, Affiliated Hosp 3, Dept Radiol, Nanchang 330008, Jiangxi, Peoples R China;
通讯作者:
通讯机构: [5]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院