当前位置: 首页 > 详情页

Turbo Fast Three-Dimensional Carotid Artery Black-Blood MRI by Combining Three-Dimensional MERGE Sequence with Compressed Sensing

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Peking Univ, Coll Engn, Beijing 100871, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing, Peoples R China; [3]Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China; [4]Peking Univ, Hosp 1, Dept Radiol, Beijing 100871, Peoples R China; [5]Peking Univ, Coll Engn, Yiheyuan Rd 5, Beijing 100871, Peoples R China
出处:
ISSN:

关键词: compressed sensing 3D-MERGE vessel wall imaging random sampling pseudo-centric phase encoding order CS-3D MERGE

摘要:
PurposeIn this study, we sought to investigate the feasibility of turbo fast three-dimensional (3D) black-blood imaging by combining a 3D motion-sensitizing driven equilibrium rapid gradient echo sequence with compressed sensing. MethodsA pseudo-centric phase encoding order was developed for compressed sensing-3D motion-sensitizing driven equilibrium rapid gradient echo to suppress flow signal in undersampled 3D k-space. Nine healthy volunteers were recruited for this study. Signal-to-tissue ratio, contrast-to-tissue ratio (CTR) and CTR efficiency (CTReff) between fully sampled and undersampled images were calculated and compared in seven subjects. Moreover, isotropic high resolution images using different compressed sensing acceleration factors were evaluated in two other subjects. ResultsWall-lumen signal-to-tissue ratio or CTR were comparable between the undersampled and the fully sampled images, while significant improvement of CTReff was achieved in the undersampled images. At an isotropic high spatial resolution of 0.7 x 0.7 x 0.7 mm(3), all undersampled images exhibited similar level of the flow suppression efficiency and the capability of delineating outer vessel wall boundary and lumen-wall interface, when compared with the fully sampled images. ConclusionThe proposed turbo fast compressed sensing 3D black-blood imaging technique improves scan efficiency without sacrificing flow suppression efficiency and vessel wall image quality. It could be a valuable tool for rapid 3D vessel wall imaging. Magn Reson Med 70:1347-1352, 2013. (c) 2012 Wiley Periodicals, Inc.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 3 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2011]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2011版] 出版当年五年平均 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者机构: [1]Peking Univ, Coll Engn, Beijing 100871, Peoples R China;
通讯作者:
通讯机构: [1]Peking Univ, Coll Engn, Beijing 100871, Peoples R China; [3]Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China; [5]Peking Univ, Coll Engn, Yiheyuan Rd 5, Beijing 100871, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院