当前位置: 首页 > 详情页

In vitro and in vivo evaluation of a small-caliber coaxial electrospun vascular graft loaded with heparin and VEGF

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Inst Heart Lung & Blood Vasc Dis, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Vasculargraft Electrospun Endothelialization Antithrombogenic Tissue engineering

摘要:
Introduction: To date, clinically available expanded polytetrafluoro-ethylene (ePTFE) vascular grafts are suboptimal for reconstructing small caliber (D < 6 mm) arteries, owing to thrombosis in early and restenosis in late stage. Our aim in this preliminary study was to fabricate a nano-fibrous vascular graft which was biofunctionalized with VEGF(165) and heparin. The short term performance was evaluated both in vitro and in vivo. Method: Four-mm caliber grafts were prepared by the coaxial-elctrospun technique, which consisted of poly(l-lactide-co-caprolactone) [P(LLA-CL)] collagen and elastin. Heparin and endothelial cell growth factor-165 (VEGF(165)) were encapsulated in the core of the fibrous. Controlled release of the heparin and VEGF(165) were evaluated for 28 days. Endothelial cells were cultured on the electrospun grafts or ePTFE grafts as controls. The cellular adhesion, proliferation and morphology were examined. Electrospun or ePTFE grafts were randomly implanted into a rabbit infrarenal aortic replacement model (n = 30) for 28 days without any antiplatelet therapy. At the termination, all grafts were examined by Doppler ultrasound and then evaluated with histology and scanning electron microscopy. Results: The cumulative release amount of heparin (6.93 +/- 1.03 mg) and VEGF165 (22.17 +/- 5.56 mu g) during 28 days were measured. Endothelial cells cultured on electrospun grafts showed significantly higher attachment efficiency and proliferation compared to the ePTFE ones (P < 0.001). At 2 h more ECs had attached to the P(LLA-CL)/Collagen/Elatin grafts (83.26 +/- 8.02%) compared to P(LLA-CL) (67.07 +/- 4.16%) and ePTFE (46.87 +/- 8.85%). ECs proliferated faster on VEGF loaded grafts (O.D = 2.9 +/- 1.2, n = 12) compared to ePTFE (O.D = 1.7 +/- 1.0, n = 12). The patency was significantly higher in electrospun grafts (86.6%) than ePTFE grafts (40.0%) (P = 0.021). Correspondingly, the microscope images of electrospun implants showed little thrombus when compared with the ePTFE implants. Conclusion: Biofunctionalized electrospun graft showed surgical properties, hemocompatibility and higher short-term patency compared with the ePTFE grafts. Despite good early performances, profound study should be designed for long-term evaluation. (C) 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 4 区 医学
小类 | 3 区 外科
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 外科
JCR分区:
出版当年[2015]版:
Q2 SURGERY
最新[2023]版:
Q1 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Inst Heart Lung & Blood Vasc Dis, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Inst Heart Lung & Blood Vasc Dis, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院