Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques

文献详情

资源类型:

收录情况: ◇ SCIE ◇ CPCI(ISTP) ◇ EI

机构: [1]Jiangsu Univ Technol, Sch Mech Engn, Changzhou 213001, Jiangsu, Peoples R China; [2]Beihang Univ, Sch Biol Sci & Med Engn, Minist Educ, Key Lab Biomech & Mechanobiol, Beijing 100191, Peoples R China; [3]Capital Med Univ, Beijing Anzhen Hosp, Radiol Dept, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Atherosclerosis Plaque composition Carotid artery stenting Restenosis Finite element analysis Stent deployment Longitudinal anatomic mismatch

摘要:
Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. (C) 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 工程技术
小类 | 3 区 工程:生物医学
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 工程:生物医学
JCR分区:
出版当年[2015]版:
Q3 ENGINEERING, BIOMEDICAL
最新[2023]版:
Q3 ENGINEERING, BIOMEDICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2015版] 出版当年五年平均 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者机构: [1]Jiangsu Univ Technol, Sch Mech Engn, Changzhou 213001, Jiangsu, Peoples R China; [2]Beihang Univ, Sch Biol Sci & Med Engn, Minist Educ, Key Lab Biomech & Mechanobiol, Beijing 100191, Peoples R China;
通讯作者:
通讯机构: [2]Beihang Univ, Sch Biol Sci & Med Engn, Minist Educ, Key Lab Biomech & Mechanobiol, Beijing 100191, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院