机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Radiol, Beijing 100029, Peoples R China; [2]Hainan Med Coll, Hosp Affiliated, Dept Radiol, Haikou 570120, Hainan Province, Peoples R China; [3]Curtin Univ, Dept Imaging & Appl Phys, Discipline Med Imaging, Perth, WA 6102, Australia
出处:
ISSN:

关键词: CT Angiography Contrast Medium High Pitch Image Quality Low Tube Voltage

摘要:
To assess the feasibility of detecting coronary arteries through high-pitch dual-source computed tomography (DSCT) thoracoabdominal angiography when using low-concentration contrast medium, low tube voltage, and iterative reconstruction. One hundred patients undergoing DSCT angiography with high-pitch data acquisition mode were prospectively enrolled in this study. Fifty patients were assigned to receive lodixanol 270 and scanned using the low tube voltage (100 kVp) technique and iterative reconstruction, while another fifty patients were assigned to lopamidol 370 and scanned under the conventional tube voltage (120 kVp) with the images were reconstructed with filtered back projection. Both subjective and objective assessment of image quality was performed and compared between the two groups by measuring the image noise, signal-to-noise ratio and contrast-to-noise ratio in the coronary arteries. Diagnostic images were obtained for 1267 of the 1325 segments (95.6%). No significant differences in image quality were found between patients given lodixanol 270 and lopamidol 370. The effective dose and contrast medium dose were 4.4 +/- 0.5 mSv and 6.7 +/- 0.6 mSv, 20.36 +/- 2.65 g and 28 +/- 1.98 g, corresponding to the lodixanol 270 and lopamidol 370 groups, respectively, with 34.3% dose reduction achieved in the low contrast medium lodixanol 270 group. High-pitch DSCT angiography of the thoracoabdominal aorta utilizing low iodine concentration contrast medium (lodixanol 270), low tube voltage, and iterative reconstruction is a feasible protocol with significant reduction in radiation dose and contrast medium, without compromising image quality.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 数学与计算生物学 4 区 核医学
最新[2023]版:
JCR分区:
出版当年[2013]版:
Q4 MATHEMATICAL & COMPUTATIONAL BIOLOGY Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Radiol, Beijing 100029, Peoples R China; [2]Hainan Med Coll, Hosp Affiliated, Dept Radiol, Haikou 570120, Hainan Province, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Beijing Inst Heart Lung & Blood Vessel Dis, Dept Radiol, Beijing 100029, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院