当前位置: 首页 > 详情页

T1 Contrast in the Myocardium and Blood Pool

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA; [2]Northwestern Univ, Dept Prevent Med, Chicago, IL 60611 USA; [3]Siemens Healthcare, Cardiovasc MR R&D, Chicago, IL USA; [4]Fourth Mil Med Univ, Peking Union Med Coll, Xijing Hosp, Dept Radiol, Xian 710032, Shaangxi, Peoples R China; [5]Capital Med Univ, Anzhen Hosp, Dept Radiol, Beijing, Peoples R China; [6]Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China; [7]Northwestern Univ, Dept Radiol, 737 N Michigan Ave,Suite 1600, Chicago, IL 60611 USA
出处:
ISSN:

关键词: T1 contrast heart contrast agent magnetic resonance imaging

摘要:
Objectives The objective of this study was to assess the evolution of T1 contrast (T1c) between cardiovascular tissues, contrast agents, and magnetic field strengths. Materials and Methods This Health Insurance Portability and Accountability Act-compliant study was approved by the institutional review board, and written informed consent was obtained from all participants. Eight healthy volunteers were recruited to undergo 4 consecutive magnetic resonance (MR) scans with the same imaging parameters. Scans 1 and 2 were performed using a 3-T MR scanner, and scans 3 and 4 were performed using a 1.5-T MR scanner. Gadofosveset trisodium (0.03 mmol/kg) was injected for scans 1 and 3, and gadopentetate dimeglumine (Gd-DTPA) (0.1 mmol/kg) was used for scans 2 and 4. Modified Look-Locker inversion recovery T1 maps with a midventricular short-axis view were acquired before contrast and repeated every 5 minutes until 45 minutes after contrast agent administration. T1 contrast tissue (T1(myocardium) - T1(blood)), T1c agent (T1(Gd-DTPA) - T1(Gadofosveset)), and T1c field (T1(3T) - T1(1.5T)) were calculated and compared using t tests. Results The T1c tissue of the 3-T scanner was larger than that of the 1.5-T scanner for both contrast agents. In both the myocardium and the blood pool, the T1c agent of the 1.5-T scanner was larger than that of the 3-T scanner. Gadofosveset trisodium exhibited a larger T1c field and T1c tissue than did Gd-DTPA. The T1c tissue induced by Gd-DTPA diminished faster than that induced by gadofosveset trisodium at both 1.5 and 3 T. Conclusions Our study demonstrates the independent effects of timing, contrast agent type, and magnetic field strength on postcontrast T1c under general physiological conditions. The behaviors of T1c can be used to tailor quantitative MR imaging protocols for various clinical purposes.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2023]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2012]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者机构: [1]Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA;
通讯作者:
通讯机构: [1]Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA; [7]Northwestern Univ, Dept Radiol, 737 N Michigan Ave,Suite 1600, Chicago, IL 60611 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院