当前位置: 首页 > 详情页

RETRACTED: Application of piezoelectric nanogenerator in medicine: bio-experiment and theoretical exploration (Retracted article. See vol. 7, pg. E65, 2015)

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Anzhen Rd 2, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: Implantable medical electronic device wearable medical electronic device piezoelectric nanogenerator body mechanical energy biomechanical energy harvester new power source

摘要:
Background: A large number of wearable and implantable electronic medical devices are widely used in clinic and playing an increasingly important role in diagnosis and treatment, but the limited battery capacity restricts their service life and function expansion. Piezoelectric nanogenerators can convert mechanical energy into electrical energy. Our experiment tries to find out if the piezoelectric nanogenerator fixed to the surface of the heart can convert the natural contractions and relaxations of the heart into stable electric energy for electronic medical devices such as pacemakers. Methods: We used Chinese miniature pig and prepared with standard open chest procedure. Then we fixed two opposite edges of the rectangular nanogenerator at the following three positions of the heart respectively to detect the electric voltage output: Position A, right ventricular surface, near the atrioventricular groove, parallel to the long axis of the heart; Position B, right ventricular surface, parallel to the atrioventricular groove; and Position C, left ventricular surface, near cardiac apex, parallel to the left anterior descending branch. Then we selected the place which has the highest voltage output to fix both ends of the nanogenerator and closed the chest of pig. We recorded the voltage output of nanogenerator under closed chest condition (natural condition) and compared the result with open chest condition. Finally we used Dopamine (positive inotropic agents) and Esmolol (negative inotropic agents) respectively to detect the relation between voltage output of nanogenerator and myocardial contractility. Results: With its both ends fixed on the surface of the heart, the piezoelectric nanogenerator produced stable voltage output from the mechanical contractions of the heart. Piezoelectric nanogenerator which was fixed at Position A produced the highest voltage output (3.1 V), compared with those fixed at Position B or Position C. The voltage is enough for the pacemaker's operation. The voltage output of piezoelectric nanogenerator at the natural condition (closed chest) was the same as the open chest condition and made a light emitting diode (LED) light continue to shine, which further confirmed its clinical application value. The voltage output of piezoelectric nanogenerator is positively correlated with the myocardial contractile force. The voltage output increased after we used positive inotropic agents and decreased after we used negative inotropic agents. Conclusions: Piezoelectric nanogenerators can convert the kinetic energy of the heart during the contractions and relaxations of the muscles to electric energy. The output voltage was stable in three positions on the surface of the heart. The highest voltage appeared on the surface of right ventricle, near atrioventricular groove, parallel to the long axis direction of the heart, which can be the potential new energy source for pacemakers. Piezoelectric nanogenerator can be used as cardiac function monitor in the future for its voltage output is positively correlated with myocardial contractile force.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2013]版:
最新[2023]版:
大类 | 3 区 医学
小类 | 4 区 呼吸系统
JCR分区:
出版当年[2012]版:
最新[2023]版:
Q3 RESPIRATORY SYSTEM

影响因子: 最新[2023版] 最新五年平均 出版当年[2012版] 出版当年五年平均 出版前一年[2011版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing Inst Heart Lung & Blood Vessel Dis, Beijing 100029, Peoples R China; [2]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Anzhen Rd 2, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16461 今日访问量:0 总访问量:871 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院