当前位置: 首页 > 详情页

Anteroapical aneurysm plication improves mechanical intraventricular dyssynchrony in patients with anterior myocardial infarction

文献详情

资源类型:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: echocardiography myocardial contraction aneurysm cardiac surgical procedure

摘要:
Background Left ventricular (LV) dyssynchrony has been described to occur in patients with myocardial infarction.Dyssynchrony of left ventricular mechanical contraction produces adverse hemodynamic consequences.This study aimed to test the capacity of geometric rebuilding by aneurysm plication to restore a more synchronous contractile pattern after a mechanical,rather than electrical,intervention.@@Methods A total of sixty patients with anterior myocardial infarction,QRS duration <120 ms,electively undergoing operation between January 2008 and January 2010 were included for analysis.Real-time 3-dimensional echocardiography was performed to assess LV function,LV systolic and diastolic dyssynchrony by measuring ejection fraction (EF),peak ejection rate (PER),peak filling rate (PFR) and LV dyssynchrony.LV dyssynchrony was defined as the systolic dyssynchrony of the time to reach the minimum systolic volume for 16 LV segments,expressed in percent cardiac cycle,systolic dyssynchrony index (SDI).We compared changes of LV dyssynchrony at different interval times.@@Results LV contraction was significantly asynchronous because preoperative SDI was higher,EF,PER and PFR were lowered.Compared with function after operation,LV mechanical intraventricular resynchronization was improved with decreased SDI ((8.7±0.5) % vs.(14.3±1.6) %,P=0.01); LV function was improved with EF increasing ((43±9)% vs.(37±7)%,P=0.001),and LV systolic and diastolic dyssynchreny was improved with more rapid PFR (199.4±15.6 vs.148.4±21.2,P=0.002) and PER (212.4±14.5 vs.156.3±26.2,P=0.001).@@Conclusions Systolic and diastolic dyssynchrony was highly prevalent in patients with aneurysm,irrespective of QRS duration.Aneurysm plication produces a mechanical intraventricular resynchronization.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
JCR分区:
出版当年[2010]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院