Improved Image Quality in Dual-Energy Abdominal CT: Comparison of Iterative Reconstruction in Image Space and Filtered Back Projection Reconstruction

文献详情

资源类型:

收录情况: ◇ SCIE

机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [2]Siemens Healthcare China, Beijing, Peoples R China; [3]Affiliated Hosp Hebei United Univ, Tangshan, Hebei, Peoples R China; [4]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: abdomen dual-energy CT image quality iterative reconstruction

摘要:
OBJECTIVE. The purpose of this study is to investigate whether an iterative reconstruction in image space (IRIS) algorithm improves the image quality of dual-energy CT abdominal examinations performed during the hepatic arterial phase. MATERIALS AND METHODS. Seventy patients with suspected liver masses underwent contrast-enhanced multiphase abdominal examination and were enrolled in the study. A dual-energy CT protocol was performed in the hepatic arterial phase (parameters: tube A, 140 kV and 90 mA; tube B, 80 kV and 382 mA; automatic tube current modulation on; and collimation, 14 x 1.2 mm). The reconstructions were performed with filtered back projection (FBP) and IRIS algorithms at a slice thickness of 3 mm and kernels of B30 and I30. The image noise was measured on the liver, aorta, and subcutaneous fat on the FBP and IRIS fusion images (m = 0.3) at the same position. The image noise and diagnostic acceptability of all images were scored by two radiologists. RESULTS. The image noise using the IRIS algorithm was lower than that using the standard FBP algorithm on the liver, aorta, and subcutaneous fat, respectively. The signal-to-noise ratio and contrast-to-noise ratio of images reconstructed with the IRIS algorithm also were significantly higher than for those reconstructed with the FBP algorithm. The diagnostic acceptability score using the IRIS algorithm was higher than that using the FBP algorithm at the same dose level (1.20 +/- 0.40 vs 1.37 +/- 0.57; p < 0.05). CONCLUSION. Compared with standard FBP reconstruction, an IRIS algorithm enables significant reduction of image noise and improvement of image quality and has the potential to decrease radiation exposure during contrast-enhanced dual-energy CT abdominal examination.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2010]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2010版] 出版当年五年平均 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China;
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China; [4]Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, 2 Anzhen Rd, Beijing 100029, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院