当前位置: 首页 > 详情页

Assessment of MRI-based anomalous diffusion changes in brain ischemic stroke with a fractional motion model

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [a]Department of Radiology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China [b]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China [c]Beijing City Key Lab for Medical Physics and Engineering, Institute of Heavy Ion Physics, School of Physics, Peking University, No. 5 Yiheyuan Road, Beijing 100871, China [d]Center for MRI Research, Academy for Advanced Interdisciplinary Studies, Peking University, No. 5 Yiheyuan Road, Beijing 100871, China [e]Beijing Intelligent Brain Cloud, Inc., Integrated Science Building, No. 5 Yiheyuan Road, Beijing 100871, China [f]Department of Neurology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China [g]McGovern Institute for Brain Research, Peking University, No. 5 Yiheyuan Road, Beijing 100871, China [h]Department of Nuclear Medicine, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China
出处:
ISSN:

关键词: Diffusion Magnetic resonance imaging Stroke

摘要:
The actual diffusion process in human brain has been shown to be anomalous comparing to that predicted with traditional diffusion MRI (dMRI) theory. Recently, dMRI based on fractional motion (FM) model has demonstrated the potential to accurately describe anomalous diffusion in vivo. In this work, we explored the potential value of FM model-based dMRI in quantificational identification of ischemic stroke and compared that with the traditional apparent diffusion coefficient (ADC). We included 23 acute stroke patients, 8 of whom finished a follow-up scan, and 22 matched healthy controls. The dMRI images were acquired by using a Stejskal-Tanner single-shot spin-echo echo-planar-imaging sequence (diffusion gradients were applied in three orthogonal directions with 25 non-zero b values ranging from 248 to 4474 s/mm2) at 3.0 T MRI. We calculated the coefficient of variation (CV) for FM-related parameters in stroke lesions, and compared the mean values for FM-related parameters and ADC by using two-sample t-tests. Correlation analysis was achieved using Pearson correlation coefficient test. In acute stroke lesions, CV for FM-related parameters showed significant increase compared with normal tissues (P < 0.01), while those of ADC didn't appear statistical difference. Mean values for FM-related parameters showed significant decrease in acute lesion (P < 0.01) and their changing pattern during follow-up was positively correlated with ADC (P < 0.005). Our results initially verified the utility of the FM-model in detecting ischemic stroke compared with traditional dMRI. © 2020 Elsevier Inc.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 化学
小类 | 2 区 光谱学 3 区 生化研究方法 3 区 物理:原子、分子和化学物理
最新[2023]版:
大类 | 3 区 化学
小类 | 2 区 光谱学 3 区 生化研究方法 3 区 物理:原子、分子和化学物理
JCR分区:
出版当年[2018]版:
Q2 PHYSICS, ATOMIC, MOLECULAR & CHEMICAL Q2 BIOCHEMICAL RESEARCH METHODS Q2 SPECTROSCOPY
最新[2023]版:
Q2 SPECTROSCOPY Q3 BIOCHEMICAL RESEARCH METHODS Q3 PHYSICS, ATOMIC, MOLECULAR & CHEMICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [a]Department of Radiology, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China [b]Beijing Key Laboratory of Magnetic Resonance Imaging and Brain Informatics, Beijing, China
共同第一作者:
通讯作者:
通讯机构: [*1]Department of Radiology & Nuclear Medicine, Xuanwu Hospital, Capital Medical University, No. 45 Changchun Street, Xicheng District, Beijing 100053, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院