How can the accuracy of SEEG be increased? An analysis of the accuracy of multilobe-spanning SEEG electrodes based on a frameless stereotactic robot-assisted system.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [2]China International Neuroscience Institute (CHINA-INI), Beijing, China [3]Center of Epilepsy, Beijing Institute for Brain Disorders, Beijing, China
出处:
ISSN:

关键词: Stereoelectroencephalography (SEEG) Robotic Stereotactic Assistance (ROSA) influencing factors epilepsy multilobe-spanning electrode

摘要:
A frameless stereotactic robot-assisted system allows stereoelectroencephalography (SEEG) electrodes to span multiple lobes. As the angularity and length are increased, maintaining accuracy of the electrodes becomes more challenging. The goal of this study was to analyze the factors that influence the accuracy of multilobe-spanning SEEG electrodes inserted using a frameless stereotactic robot-assisted system. A total of 322 SEEG electrodes were implanted in 39 patients with refractory epilepsy, and sixtyone multilobe-spanning SEEG electrodes were selected to analyze the factors that influenced the accuracy of implantation. The target error, entrance error, depth error, and angular error were calculated by a specialized computer program. Factors including electrode depth, angular deviation, referencing method, head holder choice, and use of a predrill procedure were analyzed to determine their effects on accuracy. Thirty-nine patients (aged 2-35 years, median: 19 years; 21 females) underwent frameless robotassisted SEEG electrode implantation. The mean distance between the intended target and actual tip location was 2.57±1.70 mm (range, 0.42-9.02 mm). The mean distance between the intended entrance point and the actual location was 2.2±1.29 mm (range, 0.70-6.13 mm). The mean length of the electrodes was 84.63±7.61 mm (range, 70.60-103.99 mm). The depth error was 1.36±1.22 mm (range, 0.03-6.69 mm), and the angular deviation was 1.64±1.12 degrees (range, 0.15-4.93 degrees). Multifactor regression analysis showed that entrance error, electrode depth, depth error, angular deviation, referencing method, and head holder choice could explain 59.5% of the electrode target error. Angular deviation, choice of registration approach and head holder and the use of a predrill procedure could explain 48.1% of the electrode entrance error. Use of a predrill procedure significantly reduced the electrode angular deviation (P<0.05). Head holder choice, use of a predrill procedure and angular deviation are the primary influencing factors of the accuracy of multilobe-spanning SEEG electrode placement. The Leksell frame and a predrill procedure can be used to increase the accuracy of SEEG electrode placement.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 2 区 医学
小类 | 2 区 卫生保健与服务
最新[2023]版:
JCR分区:
出版当年[2019]版:
Q3 HEALTH CARE SCIENCES & SERVICES
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China [2]China International Neuroscience Institute (CHINA-INI), Beijing, China
共同第一作者:
通讯作者:
通讯机构: [*1]Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, No. 45, Changchun Street, Xicheng District, Beijing 100053, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:16409 今日访问量:0 总访问量:869 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 首都医科大学宣武医院 技术支持:重庆聚合科技有限公司 地址:北京市西城区长椿街45号宣武医院